{"entities":{"Q979510":{"pageid":981358,"ns":120,"title":"Item:Q979510","lastrevid":65902053,"modified":"2026-04-12T06:08:54Z","type":"item","id":"Q979510","labels":{"en":{"language":"en","value":"Modelling of pulverised coal combustion by a Eulerian-Eulerian two-phase flow formulation"}},"descriptions":{"en":{"language":"en","value":"scientific article; zbMATH DE number 5727143"}},"aliases":{},"claims":{"P31":[{"mainsnak":{"snaktype":"value","property":"P31","hash":"fd5912e4dab4b881a8eb0eb27e7893fef55176ad","datavalue":{"value":{"entity-type":"item","numeric-id":56887,"id":"Q56887"},"type":"wikibase-entityid"},"datatype":"wikibase-item"},"type":"statement","id":"Q979510$C6BFB7EB-13DE-4A12-AB78-5FFC15D66534","rank":"normal"}],"P159":[{"mainsnak":{"snaktype":"value","property":"P159","hash":"2de3d012677039726aa9b31ba802692369ad551b","datavalue":{"value":{"text":"Modelling of pulverised coal combustion by a Eulerian-Eulerian two-phase flow formulation","language":"en"},"type":"monolingualtext"},"datatype":"monolingualtext"},"type":"statement","id":"Q979510$FB104C20-40A2-41C9-AFEA-29CFA885C9B9","rank":"normal"}],"P225":[{"mainsnak":{"snaktype":"value","property":"P225","hash":"22d3a41594390fb6d78f7edd2ca3b1cbaf72f385","datavalue":{"value":"1189.76728","type":"string"},"datatype":"external-id"},"type":"statement","id":"Q979510$FAC17EE6-388A-40EA-A48F-6987671B823F","rank":"normal"}],"P27":[{"mainsnak":{"snaktype":"value","property":"P27","hash":"f8da2fb6a4b362359a7af43a2939dfbe4e1ea63e","datavalue":{"value":"10.1504/PCFD.2005.007067","type":"string"},"datatype":"external-id"},"type":"statement","id":"Q979510$D51AFCB1-606A-4C61-AEF9-6FB73F09AA31","rank":"normal"}],"P16":[{"mainsnak":{"snaktype":"value","property":"P16","hash":"c3431be621f3485fa385d3422d3901cb49f4e732","datavalue":{"value":{"entity-type":"item","numeric-id":979508,"id":"Q979508"},"type":"wikibase-entityid"},"datatype":"wikibase-item"},"type":"statement","id":"Q979510$4CEB70B0-B17D-4940-8AAF-C6EB855CD57C","rank":"normal"},{"mainsnak":{"snaktype":"value","property":"P16","hash":"7558c159f3862713adb19ce59337e69bfbf526e1","datavalue":{"value":{"entity-type":"item","numeric-id":979509,"id":"Q979509"},"type":"wikibase-entityid"},"datatype":"wikibase-item"},"type":"statement","id":"Q979510$CF8001E3-9AB4-4684-8F9E-131C3CE83661","rank":"normal"},{"mainsnak":{"snaktype":"value","property":"P16","hash":"6598915aa40ebf47adf70f40ab0beb88fefc9ca1","datavalue":{"value":{"entity-type":"item","numeric-id":1670877,"id":"Q1670877"},"type":"wikibase-entityid"},"datatype":"wikibase-item"},"type":"statement","id":"Q979510$317D878A-A557-4D8C-9623-A750D691ACE1","rank":"normal"}],"P200":[{"mainsnak":{"snaktype":"value","property":"P200","hash":"4ddbb7a8e61ad0511e36eeaa4b2cf1fe84056933","datavalue":{"value":{"entity-type":"item","numeric-id":374296,"id":"Q374296"},"type":"wikibase-entityid"},"datatype":"wikibase-item"},"type":"statement","id":"Q979510$D0213432-D843-4DEF-AB38-BBB47E486626","rank":"normal"}],"P28":[{"mainsnak":{"snaktype":"value","property":"P28","hash":"d07f31a0cd05737246b69f1a0892f7cf9b796217","datavalue":{"value":{"time":"+2010-06-28T00:00:00Z","timezone":0,"before":0,"after":0,"precision":11,"calendarmodel":"http://www.wikidata.org/entity/Q1985727"},"type":"time"},"datatype":"time"},"type":"statement","id":"Q979510$E879ADD7-222D-4AB0-809E-1F336824FDEC","rank":"normal"}],"P1448":[{"mainsnak":{"snaktype":"value","property":"P1448","hash":"846efe8cfca0c29fec1d3a60fe43ed5309d910c2","datavalue":{"value":"Summary: This paper evaluates a Eulerian-Eulerian modelling of the dispersed two-phase flow in pulverised coal combustion. In contrast to the commonly employed Eulerian-Lagrangian procedures, which treat the gas phase by a Eulerian and the particulate phase by a Lagrangian frame of reference, the presently investigated approach applies a Eulerian description to both phases. In our implementation, the model is further simplified assuming a mechanical and thermal equilibrium between the phases. For validation, two- and three-dimensional furnaces with different thermal loads have been analysed. Results have been compared to those obtained by Eulerian-Lagrangian formulations and measurements. It has been shown that the present Eulerian-Eulerian approach provides a comparable overall accuracy to the Eulerian-Lagrangian formulation, with substantially lower CPU requirements for large-scale utility boilers, and, thus provides an attractive alternative for this bracket of problems.","type":"string"},"datatype":"string"},"type":"statement","id":"Q979510$61CBE1D0-277B-4CE9-A3DD-838082F13E40","rank":"normal"}],"P226":[{"mainsnak":{"snaktype":"value","property":"P226","hash":"6fce3e577e240c057c0a744dc8e4c12e066942fc","datavalue":{"value":"76V05","type":"string"},"datatype":"external-id"},"type":"statement","id":"Q979510$27F34CCA-F8AF-4E51-97C6-659EE88AC230","rank":"normal"},{"mainsnak":{"snaktype":"value","property":"P226","hash":"da2910adca9bb8c6e09cb082f86efaa614cd1124","datavalue":{"value":"80A25","type":"string"},"datatype":"external-id"},"type":"statement","id":"Q979510$37A2061A-074F-46AD-A16B-9AB14E289145","rank":"normal"}],"P1451":[{"mainsnak":{"snaktype":"value","property":"P1451","hash":"4af5203c31aca85c065cd883cdb13249e8c76eb1","datavalue":{"value":"5727143","type":"string"},"datatype":"external-id"},"type":"statement","id":"Q979510$5CE02CDC-FFDB-4038-8C54-5207DBFB8BCC","rank":"normal"}],"P1450":[{"mainsnak":{"snaktype":"value","property":"P1450","hash":"e06f7cc959f74f00e83839cfc31ffb4b20999463","datavalue":{"value":"pulverised coal combustion","type":"string"},"datatype":"string"},"type":"statement","id":"Q979510$74AE695D-8A6A-4B66-AE69-1240D170C5F6","rank":"normal"},{"mainsnak":{"snaktype":"value","property":"P1450","hash":"5b64fcf8dad06dad470a67c2499ed19ed849f8be","datavalue":{"value":"Eulerian-Eulerian modelling","type":"string"},"datatype":"string"},"type":"statement","id":"Q979510$FEB7DE45-4003-4086-843C-3C5D03F75943","rank":"normal"},{"mainsnak":{"snaktype":"value","property":"P1450","hash":"9a017491243abd6483da8ed501848b67572efee4","datavalue":{"value":"two-phase flow","type":"string"},"datatype":"string"},"type":"statement","id":"Q979510$7CB1B5D3-6609-41BB-BBAF-B2707A5BF83A","rank":"normal"},{"mainsnak":{"snaktype":"value","property":"P1450","hash":"4e3f08b89b64d47f8876b8b675d7c77297cbf576","datavalue":{"value":"combustion modelling","type":"string"},"datatype":"string"},"type":"statement","id":"Q979510$1856482F-9689-4BE3-B726-99EADC718D4F","rank":"normal"},{"mainsnak":{"snaktype":"value","property":"P1450","hash":"216b464c95db23cfffcf247944a812fb053331e1","datavalue":{"value":"CFD","type":"string"},"datatype":"string"},"type":"statement","id":"Q979510$65EE5D22-90AE-45EE-830D-FE189881400D","rank":"normal"},{"mainsnak":{"snaktype":"value","property":"P1450","hash":"8df806e38c07e7cd553794b0a9c1aa7e52a08ce4","datavalue":{"value":"computational fluid dynamics","type":"string"},"datatype":"string"},"type":"statement","id":"Q979510$4704E565-FB5F-4BF2-8771-B002560F2326","rank":"normal"}],"P12":[{"mainsnak":{"snaktype":"value","property":"P12","hash":"ab2d978867e84a6436335a532578fcc016c6095e","datavalue":{"value":"Q59896459","type":"string"},"datatype":"external-id"},"type":"statement","id":"Q979510$3EFBA0C4-CA28-4CD3-A952-DAEEC2BB6DF7","rank":"normal"}],"P1460":[{"mainsnak":{"snaktype":"value","property":"P1460","hash":"57f7fea50d2ce1b39b695c4a1313582eed405e38","datavalue":{"value":{"entity-type":"item","numeric-id":5976449,"id":"Q5976449"},"type":"wikibase-entityid"},"datatype":"wikibase-item"},"type":"statement","id":"Q979510$263E0690-9BC9-459A-BD8F-07C2B649E5FC","rank":"normal"}],"P1643":[{"mainsnak":{"snaktype":"value","property":"P1643","hash":"c549fd5fd929127c209972ca1f5a0b9869475e68","datavalue":{"value":{"entity-type":"item","numeric-id":3718418,"id":"Q3718418"},"type":"wikibase-entityid"},"datatype":"wikibase-item"},"type":"statement","qualifiers":{"P1659":[{"snaktype":"value","property":"P1659","hash":"939c96c39eb0342860b5073551c1fc502dc9510a","datavalue":{"value":{"amount":"+0.7705977559089661","unit":"1"},"type":"quantity"},"datatype":"quantity"}],"P1660":[{"snaktype":"value","property":"P1660","hash":"a327a09ea0305e98d5cf33bd4036320e19f2aed0","datavalue":{"value":{"entity-type":"item","numeric-id":6821328,"id":"Q6821328"},"type":"wikibase-entityid"},"datatype":"wikibase-item"}]},"qualifiers-order":["P1659","P1660"],"id":"Q979510$4D095ACF-D03E-4544-A7B6-66CDBEDA56BD","rank":"normal"},{"mainsnak":{"snaktype":"value","property":"P1643","hash":"1aed59961216a9be7950bebfa865bff2c079b125","datavalue":{"value":{"entity-type":"item","numeric-id":3618094,"id":"Q3618094"},"type":"wikibase-entityid"},"datatype":"wikibase-item"},"type":"statement","qualifiers":{"P1659":[{"snaktype":"value","property":"P1659","hash":"e830530667b7bbb87559a94ad7ef2d36a160451c","datavalue":{"value":{"amount":"+0.7652978301048279","unit":"1"},"type":"quantity"},"datatype":"quantity"}],"P1660":[{"snaktype":"value","property":"P1660","hash":"a327a09ea0305e98d5cf33bd4036320e19f2aed0","datavalue":{"value":{"entity-type":"item","numeric-id":6821328,"id":"Q6821328"},"type":"wikibase-entityid"},"datatype":"wikibase-item"}]},"qualifiers-order":["P1659","P1660"],"id":"Q979510$6916873A-31B7-4871-9FC6-9DED416D55F8","rank":"normal"},{"mainsnak":{"snaktype":"value","property":"P1643","hash":"008ea962e78a614da710990197604311026ac474","datavalue":{"value":{"entity-type":"item","numeric-id":5455005,"id":"Q5455005"},"type":"wikibase-entityid"},"datatype":"wikibase-item"},"type":"statement","qualifiers":{"P1659":[{"snaktype":"value","property":"P1659","hash":"e247465c8724d67988d8796f3854ec68a04cacc6","datavalue":{"value":{"amount":"+0.7533224821090698","unit":"1"},"type":"quantity"},"datatype":"quantity"}],"P1660":[{"snaktype":"value","property":"P1660","hash":"a327a09ea0305e98d5cf33bd4036320e19f2aed0","datavalue":{"value":{"entity-type":"item","numeric-id":6821328,"id":"Q6821328"},"type":"wikibase-entityid"},"datatype":"wikibase-item"}]},"qualifiers-order":["P1659","P1660"],"id":"Q979510$B7AD3C12-FA2B-4579-8D7F-7D92FC64D7D2","rank":"normal"},{"mainsnak":{"snaktype":"value","property":"P1643","hash":"48fa830bc72fed469f2d7b6adbbdfd87b6593f7e","datavalue":{"value":{"entity-type":"item","numeric-id":5436940,"id":"Q5436940"},"type":"wikibase-entityid"},"datatype":"wikibase-item"},"type":"statement","qualifiers":{"P1659":[{"snaktype":"value","property":"P1659","hash":"2bc8991d280384208e3366a41673a4efc825b7f1","datavalue":{"value":{"amount":"+0.7304356694221497","unit":"1"},"type":"quantity"},"datatype":"quantity"}],"P1660":[{"snaktype":"value","property":"P1660","hash":"a327a09ea0305e98d5cf33bd4036320e19f2aed0","datavalue":{"value":{"entity-type":"item","numeric-id":6821328,"id":"Q6821328"},"type":"wikibase-entityid"},"datatype":"wikibase-item"}]},"qualifiers-order":["P1659","P1660"],"id":"Q979510$23A13203-B3E6-4CA6-96B0-F51AD3A6F699","rank":"normal"},{"mainsnak":{"snaktype":"value","property":"P1643","hash":"92ef6ed91ffb76190f96f3a8f160f9d4acb13ec3","datavalue":{"value":{"entity-type":"item","numeric-id":3646650,"id":"Q3646650"},"type":"wikibase-entityid"},"datatype":"wikibase-item"},"type":"statement","qualifiers":{"P1659":[{"snaktype":"value","property":"P1659","hash":"2b033d32a3d7d18cb8364ccbaca58d4668ef3e04","datavalue":{"value":{"amount":"+0.7206826210021973","unit":"1"},"type":"quantity"},"datatype":"quantity"}],"P1660":[{"snaktype":"value","property":"P1660","hash":"a327a09ea0305e98d5cf33bd4036320e19f2aed0","datavalue":{"value":{"entity-type":"item","numeric-id":6821328,"id":"Q6821328"},"type":"wikibase-entityid"},"datatype":"wikibase-item"}]},"qualifiers-order":["P1659","P1660"],"id":"Q979510$8FDA2056-57D0-4B60-9E80-CE4377D3FC1D","rank":"normal"}]},"sitelinks":{"mardi":{"site":"mardi","title":"Modelling of pulverised coal combustion by a Eulerian-Eulerian two-phase flow formulation","badges":[],"url":"https://portal.mardi4nfdi.de/wiki/Modelling_of_pulverised_coal_combustion_by_a_Eulerian-Eulerian_two-phase_flow_formulation"}}}}}