Dataset: Quasi-static shear-compression tests on stone masonry walls with plaster: Influence of load history and axial load ratio
Dataset:Quasi-static shear-compression tests on stone masonry walls with plaster: Influence of load history and axial load ratio
DOI10.5281/zenodo.4318944Zenodo4318944MaRDI QIDQ6696116FDOQ6696116
Dataset published at Zenodo repository.
Michele Godio, Katrin Beyer, Shenghan Zhang, Francesco Vanin
Publication date: 12 December 2020
Copyright license: Creative Commons Attribution 4.0 International
This repository contains the results of six quasi-static cyclic shear-compression tests performed on single-leaf stone masonry walls made of limestone blocks and lime-based mortar joints. Of the six walls, four are tested under different axial load ratios, performing a cyclic load history with two cycles per increasing drift demand. Three are tested under the same axial load ratio but are subjected to different load histories, namely, one monotonic loading, one cyclic loading with two cycles per drift level and one cyclic loading with one hundred cycles per drift level. Results and details of the tests are reported in: GodioM, Vanin F, Zhang S, Beyer K(2019). Quasi-Static Shear-Compression Tests on Stone Masonry Walls with Plaster: Influence of Load History and Axial Load Ratio. Engineering Structures 192: 26478. https://doi.org/10.1016/j.engstruct.2019.04.041
This page was built for dataset: Dataset: Quasi-static shear-compression tests on stone masonry walls with plaster: Influence of load history and axial load ratio