EEG Data from a Within-Subjects Study Comparing P300 Speller Performance with Different Electrode Sets
DOI10.5281/zenodo.13870023Zenodo13870023MaRDI QIDQ6702696FDOQ6702696
Dataset published at Zenodo repository.
J. V. Ringwood, Tomas Ward, Sandra-Carina Noble
Publication date: 1 October 2024
Copyright license: Creative Commons Attribution 4.0 International
The dataset contains EEG data of 10 participants who completed a P300 speller task with different electrode sets. 4 different electrode sets were used: 4-electrode set: Pz, POz, P7 and P8 6 -electrode set: Pz, POz, P3, P4, O1 and O2 8-electrode set: Cz, Pz, POz, P3, P4, O1, O2 and Oz 16-electrode set: FC1, FC2, C3, C4, Cz, CP1, CP2, Pz, POz, P3, P4, P7, P8, O1, O2 and Oz Each participant completed 3 runs of the speller (i.e. copy-spelled 3 words) with each electrode set. 10 flashes per row and column were used for the first run of each set, 5 for the second run, and 3 for the third run. The order of the electrode sets was randomised. Subjects 1 to 5 completed the experiment in an office location with natural light, Subjects 6 to 10 completed the experiment in a different office location with artificial light. An LDA classifier was trained on 2 calibration runs for each electrode set. For the 8-electrode set, an xDAWN spatial filter was used to reduce the 8 channels to 2 xDAWN components. For the 16-electrode set, an xDAWN spatial filter was used to reduce the 16 channels to 3 xDAWN components. Each participant folder contains: calibration-signal[1/2/s].ov - unprocessed EEG signals from P300 speller runs used to calibrate the BCI (i.e. train the LDA classifier and xDAWN spatial filter, where applicable), in Openvibe (.ov) file format, see details below run-[x]-raw-[y].[ov/mat] unprocessed EEG signals from [y] electrodes for a P300 speller run with [x] flashes per row and column in Openvibe (.ov) and Matlab (.mat) file formats, see details of the runs below classifier[y].cfg - LDA classifier weights for [y] electrodes spatial-filter[y].cfg - xDAWN spatial filter weights for [y] electrodes (xDAWN spatial filter only used for the 8- and 16-electrode sets) log.txt - contains the performance in the P300 speller runs for all electrode sets The .ov and .mat files contain data from the following runs: Filename Word to be copy-spelled Number of flashes per row and column Number of electrodes used Feedback given to participant calibration-signal1 THE 12 16 no calibration-signal2 QUICK 12 16 no calibration-signals Concatenation of calibration-signal1 and calibration-signal2 run-[x]-raw-[y] DANCE x y yes This research is supported by the Irish Research Council under project ID GOIPG/2020/692 and Science Foundation Ireland under grant number 12/RC/2289_P2.
This page was built for dataset: EEG Data from a Within-Subjects Study Comparing P300 Speller Performance with Different Electrode Sets