Fluid Poisson model: non-thermal plasma

From MaRDI portal
Named after

Siméon Denis Poisson


Description

A set of continuity|balance equations for electrons, ions and neutral species, coupled to Poisson's equation for the electric potential

Contained entities
continuity equation ∂n∂t+∇⋅j=S governing equation
n represents particle number density
j represents particle fluence rate
S represents sources and sinks
t represents time
reaction kinetics model
electron energy flux (drift-diffusion) Q=wb∇ϕ−∇(Dw) governing equation
Q represents electron energy flux
w represents electron energy density
b represents mobility of electron energy
ϕ represents electric potential
D represents diffusivity of electron energy
Robin boundary condition for particle flux N⋅j=1−r1+r(qμN⋅E+12vthn) boundary condition
j represents particle fluence rate
N represents unit normal vector
q represents electric charge
μ represents electrical mobility
n represents particle number density
E represents electric field
vth represents thermal velocity
r represents reflection coefficient
Poisson's equation for the electric potential −ϵ0ϵr∇2ϕ=ρ governing equation
ϵ0 represents permittivity of vacuum
ϵr represents relative permittivity
ϕ represents electric potential
ρ represents electric charge density
particle flux (drift-diffusion) j=qnμ∇ϕ−∇(Dn) governing equation
j represents particle fluence rate
q represents electric charge
n represents particle number density
μ represents electrical mobility
ϕ represents electric potential
D represents mass diffusivity
continuity equation for electron energy ∂w∂t+∇⋅Q=−eE⋅j+S~ governing equation
w represents electron energy density
Q represents electron energy flux
t represents time
e represents elementary charge
E represents electric field
j represents electron flux density
S~ represents electron energy source
Software
FEniCS






Edit fluid Poisson model: non-thermal plasma item