Operational formulation of homodyne detection
From MaRDI portal
Abstract: We obtain the standard quadrature-phase positive operator-valued measure (POVM) for homodyne detection directly and rigorously from the POVM for photon counting without directly employing the mean field approximation for the local oscillator. In addition we obtain correction terms for the quadrature-phase POVM that are applicable for relatively weak local oscillator field strengths and typical signal states.
Recommendations
- Homodyne detection and positive operator-valued measures
- Operational theory of eight-port homodyne detection
- Quantum homodyne tomography as an informationally complete positive-operator-valued measure
- Homodyne-like detection scheme based on photon-number-resolving detectors
- A note on the measurement of phase space observables with an eight-port homodyne detector
Cited in
(23)- Optical von Neumann measurement.
- Theory of optical quadrature measurement through symmetric beamsplitter studied by virtue of the IWOP technique
- On the role of the local oscillator intensity in optical homodyne-like tomography
- Covariance matrices under Bell-like detections
- Ideal quantum Reading of optical memories
- Simultaneous continuous measurement of photon-counting and homodyne detection on a free photon field: dynamics of state reduction and the mutual influence of measurement backaction
- Detection of amplitude-squared squeezing via homodyne method
- Realistic eight-port homodyne detection and covariant phase space observables
- Moment operators of observables in the balanced homodyne detection scheme
- Optimal pointers for joint measurement of σxand σzvia homodyne detection
- Time-resolved pulsed homodyne detector and its application to measurement of pulsed squeezed states
- On the moment limit of quantum observables, with an application to the balanced homodyne detection
- A note on the measurement of phase space observables with an eight-port homodyne detector
- Homodyne detection and positive operator-valued measures
- Operational theory of eight-port homodyne detection
- Homodyne-like detection scheme based on photon-number-resolving detectors
- Local sampling of the quantum phase-space distribution of a continuous-wave optical beam
- DIALOGUE CONCERNING TWO VIEWS ON QUANTUM COHERENCE: FACTIST AND FICTIONIST
- Generalized measurement of the non-normal two-boson operator
- Degradation of a quantum directional reference frame as a random walk
- Input-output properties of the Page-Hinkley detector
- No approximate complex Fermion coherent states
- No approximate complex Fermion coherent states
This page was built for publication: Operational formulation of homodyne detection
Report a bug (only for logged in users!)Click here to report a bug for this page (MaRDI item Q3158728)