Liquid film dryout model for predicting critical heat flux in annular two-phase flow
From MaRDI portal
Publication:1045705
DOI10.1631/JZUS.A0820322zbMATH Open1177.80029MaRDI QIDQ1045705FDOQ1045705
Authors: Bo Jiao, Jun-Liang Lu, Li-min Qiu, Zhihua Gan
Publication date: 15 December 2009
Published in: Journal of Zhejiang University. Science A (Search for Journal in Brave)
Recommendations
- Critical heat flux prediction for saturated flow boiling of water in vertical tubes
- Interfacial area concentration in annular two-phase flow
- A theoretical model for the prediction of the critical heat flux in heated microchannels
- Limit conditions of steady-state countercurrent annular flow and the onset of flooding, with reference to the CHF of boiling in a bottom-closed vertical tube
- Two-phase flow boiling in small channels: a brief review
Cites Work
- Critical heat flux prediction for saturated flow boiling of water in vertical tubes
- Entrainment and desposition rates of droplets in annular two-phase flow
- Droplet deposition and interchange in annular two-phase flow
- Relation of deposition to drop size when the rate law is nonlinear
- The calculation of dryout in a rod bundle
- Rates of atomization and deposition in vertical annular flow
- Correlation of entrainment for annular flow in vertical pipes
- The roles of interfacial stability and particle dynamics in multiphase flows: a personal viewpoint
- Drops in annular two-phase flow
- New entrainment rate correlation in annular two-phase flow applicable to wide range of flow condition
Cited In (4)
- Development of the film-splitting look-up table applicable to mechanistic annular film dryout model in annulus geometry
- Limit conditions of steady-state countercurrent annular flow and the onset of flooding, with reference to the CHF of boiling in a bottom-closed vertical tube
- An annular flow model for predicting liquid carryover into austenitic superheaters
- Calculation of dryout and post-dryout heat transfer for tube geometry
This page was built for publication: Liquid film dryout model for predicting critical heat flux in annular two-phase flow
Report a bug (only for logged in users!)Click here to report a bug for this page (MaRDI item Q1045705)