Optimal design of tuned liquid column dampers for seismic response control of base-isolated structures
From MaRDI portal
(Redirected from Publication:1743560)
Recommendations
- The effect of tuned-mass dampers on the seismic response of base-isolated structures
- Performance assessment of tuned liquid column dampers under random seismic loading
- Tuned liquid column damper for structural control
- Novel fluid inerter based tuned mass dampers for optimised structural control of base-isolated buildings
- Design of coupled tuned liquid column gas dampers for multi-mode reduction in vibrating structures
Cites work
- A novel aseismic foundation system for multipurpose asymmetric buildings
- Aspects of passive control of structural vibrations
- scientific article; zbMATH DE number 44726 (Why is no real title available?)
- Performance assessment of tuned liquid column dampers under random seismic loading
- Special design of tuned liquid column-gas dampers for the control of spatial structural vibrations
- The effect of tuned-mass dampers on the seismic response of base-isolated structures
- Tuned liquid column damper for structural control
Cited in
(14)- Performance assessment of tuned liquid column dampers under random seismic loading
- Tuned liquid dampers for multi-storey structure: numerical simulation using a partitioned FSI algorithm and experimental validation
- Design of coupled tuned liquid column gas dampers for multi-mode reduction in vibrating structures
- Novel fluid inerter based tuned mass dampers for optimised structural control of base-isolated buildings
- A novel aseismic foundation system for multipurpose asymmetric buildings
- Optimal design of liquid dampers for structural vibration control based on GA and \(H_\infty\) norm
- Frequency domain nonlinear modeling and analysis of liquid-filled column dampers
- Optimum TLCD for Mitigation of Offshore Wind Turbine Dynamic Response Considering Soil–Structure Interaction
- Seismic control of structures using sloped bottom tuned liquid damper
- Optimal design of inertial amplifier base isolators for dynamic response control of multi-storey buildings
- Data generation framework for inverse modeling of nonlinear systems in structural dynamics applications
- Optimal design of short-period structures equipped with sliding tuned liquid column damper and numerical and experimental control performance evaluation
- Tuned liquid column damper inerter (TLCDI) for wind-induced vibration control of fixed-base structures
- The effect of tuned-mass dampers on the seismic response of base-isolated structures
This page was built for publication: Optimal design of tuned liquid column dampers for seismic response control of base-isolated structures
Report a bug (only for logged in users!)Click here to report a bug for this page (MaRDI item Q1743560)