Iterative image reconstruction for limited-angle CT using optimized initial image
From MaRDI portal
(Redirected from Publication:306014)
Recommendations
- An adaptive iteration reconstruction method for limited-angle CT image reconstruction
- Limited-angle CT reconstruction with generalized shrinkage operators as regularizers
- Optimization for limited angle tomography in medical image processing
- Image reconstruction model for limited-angle CT based on prior image induced relative total variation
- A non-smooth and non-convex regularization method for limited-angle CT image reconstruction
Cites work
- A theory for multiresolution signal decomposition: the wavelet representation
- Compressed sensing
- On sets of numbers accepted by P/T systems composed by join
- On the Early History of the Singular Value Decomposition
- Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information
Cited in
(14)- Image reconstruction based on nonlinear diffusion model for limited-angle computed tomography
- Limited-angle CT reconstruction with generalized shrinkage operators as regularizers
- BIFURCATION ANALYSIS OF ITERATIVE IMAGE RECONSTRUCTION METHOD FOR COMPUTED TOMOGRAPHY
- A fast regularized CT reconstruction method based on a preconditioning matrix for limited-angle fan-beam CT
- A variational proximal alternating linearized minimization in a given metric for limited-angle CT image reconstruction
- Optimization for limited angle tomography in medical image processing
- Limited-angle cone-beam computed tomography image reconstruction by total variation minimization and piecewise-constant modification
- Image reconstruction model for limited-angle CT based on prior image induced relative total variation
- Landweber iterative methods for angle-limited image reconstruction
- Application of optimal quadrature formulas for reconstruction of CT images
- A fast image reconstruction method for planar objects CT inspired by differentiation property of Fourier transform (DPFT)
- An adaptive iteration reconstruction method for limited-angle CT image reconstruction
- Guided image filtering based \(\ell_0\) gradient minimization for limited-angle CT image reconstruction
- A framelet-based iterative maximum-likelihood reconstruction algorithm for spectral CT
This page was built for publication: Iterative image reconstruction for limited-angle CT using optimized initial image
Report a bug (only for logged in users!)Click here to report a bug for this page (MaRDI item Q306014)