Modeling blood filtration in hollow fibers dialyzers coupled with patient's body dynamics
Summary: We develop a mathematical model for cross filtration in a hollow fibers dialyzer, taking into account not only the phenomena occurring within the machine, but also the redistribution of chemicals between intra- and extracellular compartments in the patient's body. The scheme for the cross flow is derived with reference to a single fiber, starting from the basic laws of fluid dynamics and exploiting the smallness of the ratio between the fiber radius and the fiber length to obtain significant simplifications. We end up with a system of integral and partial differential equations in which the input data are in principle unknown. Indeed, the blood composition is considerably altered while going through the fiber and the body reacts redistributing urea, sodium ions, etc. between intra- and extracellular compartments with its own dynamics, thus updating the various concentrations at the dialyzer inlet. Such a coupling is an essential feature of the model. We present numerical simulations, showing a reasonable agreement with the data for a specific patient taken from the literature.
- Modeling high flux hollow fibers dialyzers
- Mathematical modeling for hollow fiber dialyzer: blood and \(HCO_3^{-}\)-dialysate flow characteristics
- A physiologically based model of vascular refilling during ultrafiltration in hemodialysis
- scientific article; zbMATH DE number 2148101
- Mathematical modelling of haemodialysis. Cardiovascular response, body fluid shifts, and solute kinetics
- Numerical computation of blood flow for a patient-specific hemodialysis shunt model
- A mathematical model for the evolution of solute concentrations in a hemodialysis filter
- scientific article; zbMATH DE number 5319898
- Double porous media model for mass transfer of hemodialyzers
- A physiologically based model of vascular refilling during ultrafiltration in hemodialysis
- Comparative modeling of combined transport of water and graded-size molecules across the glomerular capillary wall
- Mathematical modeling for hollow fiber dialyzer: blood and \(HCO_3^{-}\)-dialysate flow characteristics
- scientific article; zbMATH DE number 5319898 (Why is no real title available?)
- A multi‐model approach to intravenous filter optimization
- Modeling high flux hollow fibers dialyzers
- A mathematical model for the evolution of solute concentrations in a hemodialysis filter
- Models for plasma kinetics during simultaneous therapeutic plasma exchange and extracorporeal membrane oxygenation
- Modeling hemodialysis with albumin retention
- Operating Conditions for the Hemodialysis Treatment Based on the Volume Averaging Theory
- Mathematical modelling of haemodialysis. Cardiovascular response, body fluid shifts, and solute kinetics
- Blood flow velocity and ultra-filtration velocity measured by CT imaging system inside a densely bundled hollow fiber dialyzer
This page was built for publication: Modeling blood filtration in hollow fibers dialyzers coupled with patient's body dynamics
Report a bug (only for logged in users!)Click here to report a bug for this page (MaRDI item Q332995)