A method for biomedical system modelling and physiological parameter estimation using indirectly measured input functions
From MaRDI portal
Publication:4841416
DOI10.1080/00207729508929065zbMath0853.92007MaRDI QIDQ4841416
Publication date: 17 October 1995
Published in: International Journal of Systems Science (Search for Journal in Brave)
Full work available at URL: https://doi.org/10.1080/00207729508929065
plasma; compartmental models; positron emission tomography; tissue; tracer kinetics; APTAC measurement errors; arterial time-activity curve; local cerebral metabolic rate of glucose; tracer arterial plasma time-activity curve; tracer capillary plasma time-activity curve
92C55: Biomedical imaging and signal processing
92C45: Kinetics in biochemical problems (pharmacokinetics, enzyme kinetics, etc.)
92C50: Medical applications (general)
93A99: General systems theory
Cites Work
- Qualitative and quantitative experiment design for phenomenological models - a survey
- Dynamic system identification. Experiment design and data analysis
- On parameter and structural identifiability: Nonunique observability/reconstructibility for identifiable systems, other ambiguities, and new definitions