Blood velocity estimation using ultrasound and spectral iterative adaptive approaches
DOI10.1016/J.SIGPRO.2010.12.014zbMATH Open1219.92012OpenAlexW2038876983MaRDI QIDQ548908FDOQ548908
Authors: Erik Gudmundson, Andreas Jakobsson, Jørgen A. Jensen, Petre Stoica
Publication date: 30 June 2011
Published in: Signal Processing (Search for Journal in Brave)
Full work available at URL: https://doi.org/10.1016/j.sigpro.2010.12.014
Recommendations
- Spatiotemporal filtering of sequences of ultrasound images to estimate a dense field of velocities
- A Spectral Approach to Peak Velocity Estimation of Pipe Flows from Noisy Image Sequences
- scientific article; zbMATH DE number 910692
- Alternative parallel implementations of an AR-modified covariance spectral estimator for diagnostic ultrasonic blood flow studies
- Histogram-based optical flow for motion estimation in ultrasound imaging
Biomedical imaging and signal processing (92C55) Computational methods for problems pertaining to biology (92-08) Physiological flow (92C35)
Cites Work
Cited In (4)
- Fast reconstruction of 3D blood flows from Doppler ultrasound images and reduced models
- Alternative parallel implementations of an AR-modified covariance spectral estimator for diagnostic ultrasonic blood flow studies
- Spatiotemporal filtering of sequences of ultrasound images to estimate a dense field of velocities
- Analysis of blood flow velocity and pressure signals using the multipulse method
This page was built for publication: Blood velocity estimation using ultrasound and spectral iterative adaptive approaches
Report a bug (only for logged in users!)Click here to report a bug for this page (MaRDI item Q548908)