Automated design of an FDI system for the wind turbine benchmark
Summary: We propose an FDI system for the wind turbine benchmark designed by the application of a generic automated method. No specific adaptation of the method for the wind turbine benchmark is needed, and the number of required human decisions, assumptions, as well as parameter choices is minimized. The method contains in essence three steps: generation of candidate residual generators, residual generator selection, and diagnostic test construction. The proposed FDI system performs well in spite of no specific adaptation or tuning to the benchmark. All faults in the predefined test sequence can be detected and all faults, except a double fault, can also be isolated shortly thereafter. In addition, there are no false or missed detections.
- Application of a data-driven fuzzy control design to a wind turbine benchmark model
- Data-driven techniques for the fault diagnosis of a wind turbine benchmark
- On the optimized design of next-generation wind farms
- Determination of fault operation dynamical constraints for the design of wind turbine DFIG drives
- Wind turbine design through evolutionary algorithms based on surrogate CFD methods
- A HYBRID METHOD TO DESIGN THE WIND TURBINE ROTOR