Abstract: Quantitative tissue information, like the light scattering properties, is considered as a key player in the detection of cancerous cells in medical diagnosis. A promising method to obtain these data is optical coherence tomography (OCT). In this article, we will therefore discuss the refractive index reconstruction from OCT data, employing a Gaussian beam based forward model. We consider in particular samples with a layered structure, meaning that the refractive index as a function of depth is well approximated by a piece-wise constant function. For the reconstruction, we present a layer-by-layer method where in every step the refractive index is obtained via a discretized least squares minimization. For an approximated form of the minimization problem, we present an existence and uniqueness result. The applicability of the proposed method is then verified by reconstructing refractive indices of layered media from both simulated and experimental OCT data.
Cites work
- scientific article; zbMATH DE number 1232438 (Why is no real title available?)
- Inverse acoustic and electromagnetic scattering theory.
- Layer Stripping for the Helmholtz Equation
- Layer stripping for time-harmonic Maxwell's equations with high frequency
- Mathematical methods of optical coherence tomography
- One-dimensional inverse scattering problem for optical coherence tomography
- Quantitative OCT reconstructions for dispersive media
- Reconstructing the Optical Parameters of a Layered Medium with Optical Coherence Elastography
This page was built for publication: Quantitative parameter reconstruction from optical coherence tomographic data
Report a bug (only for logged in users!)Click here to report a bug for this page (MaRDI item Q6177477)