Property / review text
 
Summary: In industrial computed tomography (CT), it is often required to inspect large objects whose size is beyond a reconstructed field of view (FOV). Some multiscan modes have been developed to acquire the complete CT projection data for a larger object using small panel detectors. In this paper, we give a non-concyclic dual-source circular cone-beam scanning geometry based on the idea of multiscan modes and propose a backprojection-filtration-based (BPF) reconstruction algorithm without data rebinning. Since the FOV calculated according to this nonconcyclic dual-source circular CT scanning geometry is larger than cardiac dual-source CT scanning geometry, our method can reconstruct larger horizontal slices (i.e., the slices perpendicular to rotation axis) than cardiac dual-source CT. The quality of CT images is expected to be superior to those obtained using larger panel detectors. The simulation results have indicated that CT images obtained by the proposed method are satisfying.
Property / review text: Summary: In industrial computed tomography (CT), it is often required to inspect large objects whose size is beyond a reconstructed field of view (FOV). Some multiscan modes have been developed to acquire the complete CT projection data for a larger object using small panel detectors. In this paper, we give a non-concyclic dual-source circular cone-beam scanning geometry based on the idea of multiscan modes and propose a backprojection-filtration-based (BPF) reconstruction algorithm without data rebinning. Since the FOV calculated according to this nonconcyclic dual-source circular CT scanning geometry is larger than cardiac dual-source CT scanning geometry, our method can reconstruct larger horizontal slices (i.e., the slices perpendicular to rotation axis) than cardiac dual-source CT. The quality of CT images is expected to be superior to those obtained using larger panel detectors. The simulation results have indicated that CT images obtained by the proposed method are satisfying. / rank
 
Normal rank
Property / Mathematics Subject Classification ID
 
Property / Mathematics Subject Classification ID: 78A10 / rank
 
Normal rank
Property / Mathematics Subject Classification ID
 
Property / Mathematics Subject Classification ID: 78A70 / rank
 
Normal rank
Property / Mathematics Subject Classification ID
 
Property / Mathematics Subject Classification ID: 94A12 / rank
 
Normal rank
Property / zbMATH DE Number
 
Property / zbMATH DE Number: 6354350 / rank
 
Normal rank
Property / MaRDI profile type
 
Property / MaRDI profile type: MaRDI publication profile / rank
 
Normal rank
links / mardi / namelinks / mardi / name
 

Latest revision as of 01:19, 5 March 2024

scientific article
Language Label Description Also known as
English
Reconstruction method for nonconcyclic dual-source circular cone-beam CT with a large field of view
scientific article

    Statements

    Reconstruction method for nonconcyclic dual-source circular cone-beam CT with a large field of view (English)
    0 references
    0 references
    0 references
    0 references
    0 references
    0 references
    13 October 2014
    0 references
    Summary: In industrial computed tomography (CT), it is often required to inspect large objects whose size is beyond a reconstructed field of view (FOV). Some multiscan modes have been developed to acquire the complete CT projection data for a larger object using small panel detectors. In this paper, we give a non-concyclic dual-source circular cone-beam scanning geometry based on the idea of multiscan modes and propose a backprojection-filtration-based (BPF) reconstruction algorithm without data rebinning. Since the FOV calculated according to this nonconcyclic dual-source circular CT scanning geometry is larger than cardiac dual-source CT scanning geometry, our method can reconstruct larger horizontal slices (i.e., the slices perpendicular to rotation axis) than cardiac dual-source CT. The quality of CT images is expected to be superior to those obtained using larger panel detectors. The simulation results have indicated that CT images obtained by the proposed method are satisfying.