Reconstruction method for nonconcyclic dual-source circular cone-beam CT with a large field of view (Q460055): Difference between revisions
From MaRDI portal
Created a new Item |
Set profile property. |
||
(3 intermediate revisions by 3 users not shown) | |||
Property / author | |||
Property / author: Gang Li / rank | |||
Property / author | |||
Property / author: Gang Li / rank | |||
Normal rank | |||
Property / review text | |||
Summary: In industrial computed tomography (CT), it is often required to inspect large objects whose size is beyond a reconstructed field of view (FOV). Some multiscan modes have been developed to acquire the complete CT projection data for a larger object using small panel detectors. In this paper, we give a non-concyclic dual-source circular cone-beam scanning geometry based on the idea of multiscan modes and propose a backprojection-filtration-based (BPF) reconstruction algorithm without data rebinning. Since the FOV calculated according to this nonconcyclic dual-source circular CT scanning geometry is larger than cardiac dual-source CT scanning geometry, our method can reconstruct larger horizontal slices (i.e., the slices perpendicular to rotation axis) than cardiac dual-source CT. The quality of CT images is expected to be superior to those obtained using larger panel detectors. The simulation results have indicated that CT images obtained by the proposed method are satisfying. | |||
Property / review text: Summary: In industrial computed tomography (CT), it is often required to inspect large objects whose size is beyond a reconstructed field of view (FOV). Some multiscan modes have been developed to acquire the complete CT projection data for a larger object using small panel detectors. In this paper, we give a non-concyclic dual-source circular cone-beam scanning geometry based on the idea of multiscan modes and propose a backprojection-filtration-based (BPF) reconstruction algorithm without data rebinning. Since the FOV calculated according to this nonconcyclic dual-source circular CT scanning geometry is larger than cardiac dual-source CT scanning geometry, our method can reconstruct larger horizontal slices (i.e., the slices perpendicular to rotation axis) than cardiac dual-source CT. The quality of CT images is expected to be superior to those obtained using larger panel detectors. The simulation results have indicated that CT images obtained by the proposed method are satisfying. / rank | |||
Normal rank | |||
Property / Mathematics Subject Classification ID | |||
Property / Mathematics Subject Classification ID: 78A10 / rank | |||
Normal rank | |||
Property / Mathematics Subject Classification ID | |||
Property / Mathematics Subject Classification ID: 78A70 / rank | |||
Normal rank | |||
Property / Mathematics Subject Classification ID | |||
Property / Mathematics Subject Classification ID: 94A12 / rank | |||
Normal rank | |||
Property / zbMATH DE Number | |||
Property / zbMATH DE Number: 6354350 / rank | |||
Normal rank | |||
Property / MaRDI profile type | |||
Property / MaRDI profile type: MaRDI publication profile / rank | |||
Normal rank | |||
links / mardi / name | links / mardi / name | ||
Latest revision as of 01:19, 5 March 2024
scientific article
Language | Label | Description | Also known as |
---|---|---|---|
English | Reconstruction method for nonconcyclic dual-source circular cone-beam CT with a large field of view |
scientific article |
Statements
Reconstruction method for nonconcyclic dual-source circular cone-beam CT with a large field of view (English)
0 references
13 October 2014
0 references
Summary: In industrial computed tomography (CT), it is often required to inspect large objects whose size is beyond a reconstructed field of view (FOV). Some multiscan modes have been developed to acquire the complete CT projection data for a larger object using small panel detectors. In this paper, we give a non-concyclic dual-source circular cone-beam scanning geometry based on the idea of multiscan modes and propose a backprojection-filtration-based (BPF) reconstruction algorithm without data rebinning. Since the FOV calculated according to this nonconcyclic dual-source circular CT scanning geometry is larger than cardiac dual-source CT scanning geometry, our method can reconstruct larger horizontal slices (i.e., the slices perpendicular to rotation axis) than cardiac dual-source CT. The quality of CT images is expected to be superior to those obtained using larger panel detectors. The simulation results have indicated that CT images obtained by the proposed method are satisfying.
0 references