Coupling influence on signal readout of a dual-parameter LC resonant system (Q277876): Difference between revisions

From MaRDI portal
Importer (talk | contribs)
Created a new Item
 
Created claim: Wikidata QID (P12): Q59102479, #quickstatements; #temporary_batch_1712111774907
 
(5 intermediate revisions by 5 users not shown)
Property / review text
 
Summary: Dual-parameter inductive-capacitive (LC) resonant sensor is gradually becoming the measurement trend in complex harsh environments; however, the coupling between inductors greatly affects the readout signal, which becomes very difficult to resolve by means of simple mathematical tools. By changing the values of specific variables in a MATLAB code, the influence of coupling between coils on the readout signal is analyzed. Our preliminary conclusions underline that changing the coupling to antenna greatly affects the readout signal, but it simultaneously influences the other signal. When \(f_{01} = f_{02}\), it is better to broaden the difference between the two coupling coefficients \(k_1\) and \(k_2\). On the other side, when \(f_{01}\) is smaller than \(f_{02}\), it is better to decrease the coupling between sensor inductors \(k_{12}\), in order to obtain two readout signals averaged in strength. Finally, a test system including a discrete capacitor soldered to a printed circuit board (PCB) based planar spiral coil is built, and the readout signals under different relative inductors positions are analyzed. All experimental results are in good agreement with the results of the MATLAB simulation.
Property / review text: Summary: Dual-parameter inductive-capacitive (LC) resonant sensor is gradually becoming the measurement trend in complex harsh environments; however, the coupling between inductors greatly affects the readout signal, which becomes very difficult to resolve by means of simple mathematical tools. By changing the values of specific variables in a MATLAB code, the influence of coupling between coils on the readout signal is analyzed. Our preliminary conclusions underline that changing the coupling to antenna greatly affects the readout signal, but it simultaneously influences the other signal. When \(f_{01} = f_{02}\), it is better to broaden the difference between the two coupling coefficients \(k_1\) and \(k_2\). On the other side, when \(f_{01}\) is smaller than \(f_{02}\), it is better to decrease the coupling between sensor inductors \(k_{12}\), in order to obtain two readout signals averaged in strength. Finally, a test system including a discrete capacitor soldered to a printed circuit board (PCB) based planar spiral coil is built, and the readout signals under different relative inductors positions are analyzed. All experimental results are in good agreement with the results of the MATLAB simulation. / rank
 
Normal rank
Property / Mathematics Subject Classification ID
 
Property / Mathematics Subject Classification ID: 94A12 / rank
 
Normal rank
Property / zbMATH DE Number
 
Property / zbMATH DE Number: 6575778 / rank
 
Normal rank
Property / describes a project that uses
 
Property / describes a project that uses: Matlab / rank
 
Normal rank
Property / MaRDI profile type
 
Property / MaRDI profile type: MaRDI publication profile / rank
 
Normal rank
Property / full work available at URL
 
Property / full work available at URL: https://doi.org/10.1155/2015/437869 / rank
 
Normal rank
Property / OpenAlex ID
 
Property / OpenAlex ID: W1594915279 / rank
 
Normal rank
Property / Wikidata QID
 
Property / Wikidata QID: Q59102479 / rank
 
Normal rank
links / mardi / namelinks / mardi / name
 

Latest revision as of 03:36, 3 April 2024

scientific article
Language Label Description Also known as
English
Coupling influence on signal readout of a dual-parameter LC resonant system
scientific article

    Statements

    Coupling influence on signal readout of a dual-parameter LC resonant system (English)
    0 references
    0 references
    0 references
    0 references
    0 references
    0 references
    0 references
    0 references
    2 May 2016
    0 references
    Summary: Dual-parameter inductive-capacitive (LC) resonant sensor is gradually becoming the measurement trend in complex harsh environments; however, the coupling between inductors greatly affects the readout signal, which becomes very difficult to resolve by means of simple mathematical tools. By changing the values of specific variables in a MATLAB code, the influence of coupling between coils on the readout signal is analyzed. Our preliminary conclusions underline that changing the coupling to antenna greatly affects the readout signal, but it simultaneously influences the other signal. When \(f_{01} = f_{02}\), it is better to broaden the difference between the two coupling coefficients \(k_1\) and \(k_2\). On the other side, when \(f_{01}\) is smaller than \(f_{02}\), it is better to decrease the coupling between sensor inductors \(k_{12}\), in order to obtain two readout signals averaged in strength. Finally, a test system including a discrete capacitor soldered to a printed circuit board (PCB) based planar spiral coil is built, and the readout signals under different relative inductors positions are analyzed. All experimental results are in good agreement with the results of the MATLAB simulation.
    0 references

    Identifiers