A three-way array model for resolving multicomponent fluorescent mixtures (Q1207190): Difference between revisions

From MaRDI portal
RedirectionBot (talk | contribs)
Changed an Item
ReferenceBot (talk | contribs)
Changed an Item
 
(2 intermediate revisions by 2 users not shown)
Property / describes a project that uses
 
Property / describes a project that uses: EISPACK / rank
 
Normal rank
Property / MaRDI profile type
 
Property / MaRDI profile type: MaRDI publication profile / rank
 
Normal rank
Property / cites work
 
Property / cites work: Matrix eigensystem routines - EISPACK guide. 2nd ed / rank
 
Normal rank
Property / cites work
 
Property / cites work: Matrix eigensystem routines. EISPACK guide extension / rank
 
Normal rank
Property / cites work
 
Property / cites work: Q5185900 / rank
 
Normal rank
Property / cites work
 
Property / cites work: Principal component analysis of three-mode data by means of alternating least squares algorithms / rank
 
Normal rank
Property / cites work
 
Property / cites work: Q3339960 / rank
 
Normal rank
Property / cites work
 
Property / cites work: An Algorithm for Least-Squares Estimation of Nonlinear Parameters / rank
 
Normal rank

Latest revision as of 15:37, 17 May 2024

scientific article
Language Label Description Also known as
English
A three-way array model for resolving multicomponent fluorescent mixtures
scientific article

    Statements

    A three-way array model for resolving multicomponent fluorescent mixtures (English)
    0 references
    0 references
    0 references
    0 references
    1 April 1993
    0 references
    The lifetime of a fluorescent species is defined as the time for the fluorescence emission reduced to \(1/e\) of its initial intensity following excitation by a pulse of light with negligible duration. In this paper a method is presented which can be applied to analyze the three dimensional excitation-emission frequency array in which the measured emission intensity is a function of excitation wavelength, emission wavelength and modulation frequency. It is shown that the method can uniquely resolve individual spectra and extract lifetimes, provided that the fluorescence lifetimes for the individual components are different. No individual conjectures are needed for the unknown spectra, and the number of components that can be resolved is limited only by the number of excitations or emission wavelengths and by the signal to noise ratio.
    0 references
    0 references
    0 references
    0 references
    0 references
    0 references
    excitation-emission frequency array
    0 references
    phase-resolved fluorescence spectroscopy
    0 references
    excitation-emission matrices
    0 references
    multicomponent spectra
    0 references