Research on fault diagnosis of flexible material R2R manufacturing system based on quality control chart and SoV (Q1721228): Difference between revisions

From MaRDI portal
Import240304020342 (talk | contribs)
Set profile property.
ReferenceBot (talk | contribs)
Changed an Item
(One intermediate revision by one other user not shown)
Property / full work available at URL
 
Property / full work available at URL: https://doi.org/10.1155/2018/6350380 / rank
 
Normal rank
Property / OpenAlex ID
 
Property / OpenAlex ID: W2803243130 / rank
 
Normal rank
Property / cites work
 
Property / cites work: Application of copulas to multivariate control charts / rank
 
Normal rank
Property / cites work
 
Property / cites work: Multivariate nonparametric control chart with variable sampling interval / rank
 
Normal rank
Property / cites work
 
Property / cites work: Distribution-free exponentially weighted moving average control charts for monitoring unknown location / rank
 
Normal rank

Revision as of 03:17, 18 July 2024

scientific article
Language Label Description Also known as
English
Research on fault diagnosis of flexible material R2R manufacturing system based on quality control chart and SoV
scientific article

    Statements

    Research on fault diagnosis of flexible material R2R manufacturing system based on quality control chart and SoV (English)
    0 references
    0 references
    0 references
    0 references
    0 references
    8 February 2019
    0 references
    Summary: The Stream of Variation (SoV) model and control chart are combined to study the fault diagnosis method of flexible materials R2R manufacturing system. Based on the analysis of the correlation between the fault source and product quality in the manufacturing process and also the statistical distribution rule of the processing quality characteristic vector \(L_i\) and the fault source \(f_i\), SoV model under controlled or uncontrolled states and the mathematical model of the probability distribution of the statistic \(T_{i, m}^2\) of the quality characteristic variable \(L_i\) are deduced. And the calculation equation of the centerline, the upper limit, and the lower limit of the control chart are deduced. The experimental results show that, under controlled or uncontrolled condition, when the program runs to 500 steps, the Average Run Length (ARL) of the performance parameters tends to be stable; and when program reaches 1000 steps, the actual ARL value is almost the same as the theoretical value. The fault diagnosis experiment shows that, under the condition when the fault source is strongly correlated or the fault source correlation coefficient is the same, using the control chart established in this paper can simply and quickly determine the fault location in the system.
    0 references

    Identifiers