Accurate finite difference schemes for solving a 3D micro heat transfer model in an N-carrier system with the Neumann boundary condition in spherical coordinates (Q708307): Difference between revisions
From MaRDI portal
ReferenceBot (talk | contribs) Changed an Item |
Normalize DOI. |
||
(2 intermediate revisions by 2 users not shown) | |||
Property / DOI | |||
Property / DOI: 10.1016/j.cam.2010.07.017 / rank | |||
Property / DOI | |||
Property / DOI: 10.1016/J.CAM.2010.07.017 / rank | |||
Normal rank |
Latest revision as of 01:25, 10 December 2024
scientific article
Language | Label | Description | Also known as |
---|---|---|---|
English | Accurate finite difference schemes for solving a 3D micro heat transfer model in an N-carrier system with the Neumann boundary condition in spherical coordinates |
scientific article |
Statements
Accurate finite difference schemes for solving a 3D micro heat transfer model in an N-carrier system with the Neumann boundary condition in spherical coordinates (English)
0 references
11 October 2010
0 references
The paper deals with a 3D micro heat transfer model in an \(N\)-carrier system with a Neumann boundary condition in spherical coordinates which describes the non-equilibrium heating in biological cells. Two modified Crank-Nicolson schemes are presented. One of them is based on the fictious boundary at the center of the cell and the other is obtained without using the fictious boundary condition. The truncation errors are of second order with respect to the spatial variable. Both schemes are shown to be unconditionally stable. Numerical tests show that the convergence rate of both schemes is about \(2.0\) in space.
0 references
micro heat transfer model
0 references
Neumann boundary conditions
0 references
Crank-Nicolson difference scheme
0 references
stability
0 references
convergence
0 references
numerical examples
0 references
error bounds
0 references
\(N\)-carrier system
0 references
0 references