Inferential control applications (Q1064296): Difference between revisions

From MaRDI portal
RedirectionBot (talk | contribs)
Changed an Item
Import240304020342 (talk | contribs)
Set profile property.
Property / MaRDI profile type
 
Property / MaRDI profile type: MaRDI publication profile / rank
 
Normal rank

Revision as of 02:04, 5 March 2024

scientific article
Language Label Description Also known as
English
Inferential control applications
scientific article

    Statements

    Inferential control applications (English)
    0 references
    0 references
    0 references
    0 references
    1985
    0 references
    In high-order, long-dead-time processes, inferential control systems will generally outperform conventional feedback control systems. To implement inferential control the user must know how to - tune the inferential controller on line, - avoid control degradation due to saturation of the control effort, - smooth manual-automatic switching, - design a cascade control system. In addition, the user should be able to determine whether the benefits of inferential control justify its selection over a PID control system. This report presents ways to meet these requirements and applies the methods to an industrial autoclave plant and to a laboratory heat exchange system.
    0 references
    inferential control
    0 references
    feedback control
    0 references
    saturation
    0 references
    cascade control
    0 references

    Identifiers