Extended finite element method with simplified spherical harmonics approximation for the forward model of optical molecular imaging (Q1929553): Difference between revisions

From MaRDI portal
Set OpenAlex properties.
ReferenceBot (talk | contribs)
Changed an Item
 
Property / cites work
 
Property / cites work: Light transport in biological tissue based on the simplified spherical harmonics equations / rank
 
Normal rank
Property / cites work
 
Property / cites work: The inverse source problem based on the radiative transfer equation in optical molecular imaging / rank
 
Normal rank
Property / cites work
 
Property / cites work: A finite element method for crack growth without remeshing / rank
 
Normal rank
Property / cites work
 
Property / cites work: The extended finite element method (XFEM) for solidification problems / rank
 
Normal rank

Latest revision as of 01:26, 6 July 2024

scientific article
Language Label Description Also known as
English
Extended finite element method with simplified spherical harmonics approximation for the forward model of optical molecular imaging
scientific article

    Statements

    Extended finite element method with simplified spherical harmonics approximation for the forward model of optical molecular imaging (English)
    0 references
    0 references
    0 references
    0 references
    0 references
    0 references
    9 January 2013
    0 references
    Summary: An extended finite element method (XFEM) for the forward model of 3D optical molecular imaging is developed with simplified spherical harmonics approximation (SP\(_N\)). In the XFEM scheme of SP\(_N\) equations, the signed distance function is employed to accurately represent the internal tissue boundary, and then it is used to construct the enriched basis function of the finite element scheme. Therefore, the finite element calculation can be carried out without the time-consuming internal boundary mesh generation. Moreover, the required overly fine mesh conforming to the complex tissue boundary which leads to excess time cost can be avoided. XFEM conveniences its application to tissues with complex internal structure and improves the computational efficiency. Phantom and digital mouse experiments were carried out to validate the efficiency of the proposed method. Compared with standard finite element method and classical Monte Carlo (MC) method, the validation results show the merits and potential of the XFEM for optical imaging.
    0 references

    Identifiers

    0 references
    0 references
    0 references
    0 references
    0 references
    0 references
    0 references