Medical image fusion based on rolling guidance filter and spiking cortical model (Q308738): Difference between revisions

From MaRDI portal
Importer (talk | contribs)
Created a new Item
 
Importer (talk | contribs)
Changed an Item
Property / review text
 
Summary: Medical image fusion plays an important role in diagnosis and treatment of diseases such as image-guided radiotherapy and surgery. Although numerous medical image fusion methods have been proposed, most of these approaches are sensitive to the noise and usually lead to fusion image distortion, and image information loss. Furthermore, they lack universality when dealing with different kinds of medical images. In this paper, we propose a new medical image fusion to overcome the aforementioned issues of the existing methods. It is achieved by combining with rolling guidance filter (RGF) and spiking cortical model (SCM). Firstly, saliency of medical images can be captured by RGF. Secondly, a self-adaptive threshold of SCM is gained by utilizing the mean and variance of the source images. Finally, fused image can be gotten by SCM motivated by RGF coefficients. Experimental results show that the proposed method is superior to other current popular ones in both subjectively visual performance and objective criteria.
Property / review text: Summary: Medical image fusion plays an important role in diagnosis and treatment of diseases such as image-guided radiotherapy and surgery. Although numerous medical image fusion methods have been proposed, most of these approaches are sensitive to the noise and usually lead to fusion image distortion, and image information loss. Furthermore, they lack universality when dealing with different kinds of medical images. In this paper, we propose a new medical image fusion to overcome the aforementioned issues of the existing methods. It is achieved by combining with rolling guidance filter (RGF) and spiking cortical model (SCM). Firstly, saliency of medical images can be captured by RGF. Secondly, a self-adaptive threshold of SCM is gained by utilizing the mean and variance of the source images. Finally, fused image can be gotten by SCM motivated by RGF coefficients. Experimental results show that the proposed method is superior to other current popular ones in both subjectively visual performance and objective criteria. / rank
 
Normal rank
Property / Mathematics Subject Classification ID
 
Property / Mathematics Subject Classification ID: 92C55 / rank
 
Normal rank
Property / zbMATH DE Number
 
Property / zbMATH DE Number: 6623962 / rank
 
Normal rank
Property / zbMATH Keywords
 
rolling guidance filter
Property / zbMATH Keywords: rolling guidance filter / rank
 
Normal rank
Property / zbMATH Keywords
 
spiking cortical model
Property / zbMATH Keywords: spiking cortical model / rank
 
Normal rank
Property / zbMATH Keywords
 
self-adaptive threshold
Property / zbMATH Keywords: self-adaptive threshold / rank
 
Normal rank
Property / zbMATH Keywords
 
RGF coefficients
Property / zbMATH Keywords: RGF coefficients / rank
 
Normal rank

Revision as of 23:32, 27 June 2023

scientific article
Language Label Description Also known as
English
Medical image fusion based on rolling guidance filter and spiking cortical model
scientific article

    Statements

    Medical image fusion based on rolling guidance filter and spiking cortical model (English)
    0 references
    0 references
    0 references
    0 references
    6 September 2016
    0 references
    Summary: Medical image fusion plays an important role in diagnosis and treatment of diseases such as image-guided radiotherapy and surgery. Although numerous medical image fusion methods have been proposed, most of these approaches are sensitive to the noise and usually lead to fusion image distortion, and image information loss. Furthermore, they lack universality when dealing with different kinds of medical images. In this paper, we propose a new medical image fusion to overcome the aforementioned issues of the existing methods. It is achieved by combining with rolling guidance filter (RGF) and spiking cortical model (SCM). Firstly, saliency of medical images can be captured by RGF. Secondly, a self-adaptive threshold of SCM is gained by utilizing the mean and variance of the source images. Finally, fused image can be gotten by SCM motivated by RGF coefficients. Experimental results show that the proposed method is superior to other current popular ones in both subjectively visual performance and objective criteria.
    0 references
    rolling guidance filter
    0 references
    spiking cortical model
    0 references
    self-adaptive threshold
    0 references
    RGF coefficients
    0 references

    Identifiers