Active fault-tolerant control for wind turbine with simultaneous actuator and sensor faults (Q680799): Difference between revisions

From MaRDI portal
Changed an Item
Import240304020342 (talk | contribs)
Set profile property.
Property / MaRDI profile type
 
Property / MaRDI profile type: MaRDI publication profile / rank
 
Normal rank

Revision as of 00:57, 5 March 2024

scientific article
Language Label Description Also known as
English
Active fault-tolerant control for wind turbine with simultaneous actuator and sensor faults
scientific article

    Statements

    Active fault-tolerant control for wind turbine with simultaneous actuator and sensor faults (English)
    0 references
    0 references
    0 references
    0 references
    0 references
    0 references
    0 references
    29 January 2018
    0 references
    Summary: The purpose of this paper is to show a novel fault-tolerant tracking control (FTC) strategy with robust fault estimation and compensating for simultaneous actuator sensor faults. Based on the framework of fault-tolerant control, developing an FTC design method for wind turbines is a challenge and, thus, they can tolerate simultaneous pitch actuator and pitch sensor faults having bounded first time derivatives. The paper's key contribution is proposing a descriptor sliding mode method, in which for establishing a novel augmented descriptor system, with which we can estimate the state of system and reconstruct fault by designing descriptor sliding mode observer, the paper introduces an auxiliary descriptor state vector composed by a system state vector, actuator fault vector, and sensor fault vector. By the optimized method of LMI, the conditions for stability that estimated error dynamics are set up to promote the determination of the parameters designed. With this estimation, and designing a fault-tolerant controller, the system's stability can be maintained. The effectiveness of the design strategy is verified by implementing the controller in the National Renewable Energy Laboratory's 5-MW nonlinear, high-fidelity wind turbine model (FAST) and simulating it in MATLAB/Simulink.
    0 references
    fault-tolerant tracking control (FTC)
    0 references
    wind turbine
    0 references
    simultaneous actuator and sensor faults
    0 references
    descriptor sliding mode
    0 references
    stability
    0 references
    high-fidelity wind turbine model (FAST)
    0 references
    0 references
    0 references

    Identifiers

    0 references
    0 references
    0 references
    0 references
    0 references
    0 references
    0 references
    0 references