Nonuniform multiple slot injection (suction) or wall enthalpy into a steady compressible laminar boundary layer (Q1580379): Difference between revisions

From MaRDI portal
Added link to MaRDI item.
Import240304020342 (talk | contribs)
Set profile property.
Property / MaRDI profile type
 
Property / MaRDI profile type: MaRDI publication profile / rank
 
Normal rank

Revision as of 05:00, 5 March 2024

scientific article
Language Label Description Also known as
English
Nonuniform multiple slot injection (suction) or wall enthalpy into a steady compressible laminar boundary layer
scientific article

    Statements

    Nonuniform multiple slot injection (suction) or wall enthalpy into a steady compressible laminar boundary layer (English)
    0 references
    0 references
    0 references
    2000
    0 references
    The aim is to study the effects of nonuniform multiple slot injection (suction) and nonuniform total enthalpy at the wall on steady nonsimilar compressible boundary layer flows over two-dimensional and axi-symmetric bodies. The nonsimilar solutions are obtained starting from the origin of the streamwise coordinate to the point of separation. The nonlinear coupled partial differential equations of the problem are first linearized using quasi-linearization method, and then the resulting linear partial differential equations are expressed in difference form. It is found that the nonuniform multiple slot injection moves the point of separation downstream, but the nonuniform multiple slot suction has the reverse effect.
    0 references
    0 references
    nonsimilar solutions
    0 references
    separation
    0 references
    quasi-linearization
    0 references