Robust design of terminal ILC with \(H_{\infty}\) mixed sensitivity approach for a thermoforming oven (Q983348): Difference between revisions
From MaRDI portal
Set profile property. |
Set OpenAlex properties. |
||
Property / full work available at URL | |||
Property / full work available at URL: https://doi.org/10.1155/2008/289391 / rank | |||
Normal rank | |||
Property / OpenAlex ID | |||
Property / OpenAlex ID: W2044832602 / rank | |||
Normal rank |
Revision as of 21:25, 19 March 2024
scientific article
Language | Label | Description | Also known as |
---|---|---|---|
English | Robust design of terminal ILC with \(H_{\infty}\) mixed sensitivity approach for a thermoforming oven |
scientific article |
Statements
Robust design of terminal ILC with \(H_{\infty}\) mixed sensitivity approach for a thermoforming oven (English)
0 references
22 July 2010
0 references
Summary: This paper presents a robust design approach for terminal iterative learning control (TILC). This robust design uses the \(H_{\infty }\) mixed-sensitivity technique. An industrial application is described where TILC is used to control the reheat phase of plastic sheets in a thermoforming oven. The TILC adjusts the heater temperature setpoints such that, at the end of the reheat cycle, the surface temperature map of the plastic sheet will converge to the desired one. Simulation results are included to show the effectiveness of the control law.
0 references