Air Quality (Q6767954): Difference between revisions
From MaRDI portal
Removed claim: cites work (P223): On field calibration of an electronic nose for benzene estimation in an urban pollution monitoring scenario (Q5705757) Tag: Manual revert |
|||
| Property / cites work | |||
| Property / cites work: On field calibration of an electronic nose for benzene estimation in an urban pollution monitoring scenario / rank | |||
Normal rank | |||
Revision as of 23:24, 14 April 2025
Dataset in the Graphical Modelling and Causal Inference Zenodo Community
| Language | Label | Description | Also known as |
|---|---|---|---|
| English | Air Quality |
Dataset in the Graphical Modelling and Causal Inference Zenodo Community |
Statements
3 February 2025
0 references
This dataset represents hourly averaged measurements of 5 metal oxide chemical sensors embedded in an air quality chemical multisensor device. The certified analyzer was located on the field in a significantly polluted area, at road level, within an Italian city. Data were recorded from March 2004 to February 2005 (one year), representing the longest freely available recordings of on-field deployed air quality chemical sensor device responses (De Vitoet et al., 2008). Task: The dataset can be used to study causal discovery methods. Summary: Size of dataset: 9357 x 15Task: Causal Discovery ProblemData Type: Mixed DataDataset Scope: Standalone DatasetGround Truth: Unknown GraphTemporal Structure: Time Series DataLicense: CC BY 4.0 (see https://archive.ics.uci.edu/dataset/360/air+quality)Missing Values: No Missing Values Missingness Statement: There are no missing values. Features:Date: (DD/MM/YYYY)Time: (HH.MM.SS)CO(GT): True hourly averaged concentration CO in mg/m^3 (reference analyzer)PT08.S1(CO): (tin oxide) hourly averaged sensor response (nominally CO targeted)NMHC(GT): True hourly averaged overall Non Metanic HydroCarbons concentration in microg/m^3 (reference analyzer)C6H6(GT): True hourly averaged Benzene concentration in microg/m^3 (reference analyzer)PT08.S2(NMHC): (titania) hourly averaged sensor response (nominally NMHC targeted)NOx(GT): True hourly averaged NOx concentration in ppb (reference analyzer)PT08.S3(NOx): (tungsten oxide) hourly averaged sensor response (nominally NOx targeted)NO2(GT): True hourly averaged NO2 concentration in microg/m^3 (reference analyzer)PT08.S4(NO2): (tungsten oxide) hourly averaged sensor response (nominally NO2 targeted)PT08.S5(O3): (indium oxide) hourly averaged sensor response (nominally O3 targeted)T: Temperature in °CRH: Relative Humidity (%)AH: Absolute Humidity Files: AirQuality.csv: dataset
0 references
1
0 references