Improved CEEMDAN and PSO-SVR modeling for near-infrared noninvasive glucose detection (Q519844)

From MaRDI portal
Revision as of 18:23, 27 June 2024 by Daniel (talk | contribs) (‎Created claim: Wikidata QID (P12): Q41014575, #quickstatements; #temporary_batch_1719508928570)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
scientific article
Language Label Description Also known as
English
Improved CEEMDAN and PSO-SVR modeling for near-infrared noninvasive glucose detection
scientific article

    Statements

    Improved CEEMDAN and PSO-SVR modeling for near-infrared noninvasive glucose detection (English)
    0 references
    0 references
    0 references
    7 April 2017
    0 references
    Summary: Diabetes is a serious threat to human health. Thus, research on noninvasive blood glucose detection has become crucial locally and abroad. Near-infrared transmission spectroscopy has important applications in noninvasive glucose detection. Extracting useful information and selecting appropriate modeling methods can improve the robustness and accuracy of models for predicting blood glucose concentrations. Therefore, an improved signal reconstruction and calibration modeling method is proposed in this study. On the basis of improved complete ensemble empirical mode decomposition with adaptive noise (CEEMDAN) and correlative coefficient, the sensitive intrinsic mode functions are selected to reconstruct spectroscopy signals for developing the calibration model using the support vector regression (SVR) method. The radial basis function kernel is selected for SVR, and three parameters, namely, insensitive loss coefficient \(\varepsilon\), penalty parameter \(C\), and width coefficient \(\gamma\), are identified beforehand for the corresponding model. Particle swarm optimization (PSO) is employed to optimize the simultaneous selection of the three parameters. Results of the comparison experiments using PSO-SVR and partial least squares show that the proposed signal reconstitution method is feasible and can eliminate noise in spectroscopy signals. The prediction accuracy of model using PSO-SVR method is also found to be better than that of other methods for near-infrared noninvasive glucose detection.
    0 references
    complete ensemble empirical mode decomposition with adaptive noise
    0 references
    support vector regression
    0 references
    particle swarm optimization