CONDIF: A modified central-difference scheme for convective flows

From MaRDI portal





For most practical purposes, the central-difference scheme (CDS) would be ideal only if it were unconditionally stable. It is a simple, and second- order scheme which is easy to implement. It does not introduce any second-order 'diffusion' like truncation error. However, for grid Peclet numbers larger than 2, the CDS leads to over- and under-shoots and is unstable. This paper presents a method, called CONDIF, which eliminates this undesirable feature of the CDS. It modifies the CDS by introducing a controlled amount of numerical diffusion based on the local gradients. The numerical diffusion can be adjusted to be negligibly low for most problems. CONDIF has been used to solve a number of test problems which have been widely used for comparative study of numerical schemes in the published literature.











This page was built for publication: CONDIF: A modified central-difference scheme for convective flows

Report a bug (only for logged in users!)Click here to report a bug for this page (MaRDI item Q3757619)