An optimum reinforcement solution for a torsionless grillage with given minimum strength (Q1083290)

From MaRDI portal

!

This is the item page for this Wikibase entity, intended for internal use and editing purposes. Please use the normal view instead:

scientific article; zbMATH DE number 3976551
Language Label Description Also known as
default for all languages
No label defined
    English
    An optimum reinforcement solution for a torsionless grillage with given minimum strength
    scientific article; zbMATH DE number 3976551

      Statements

      An optimum reinforcement solution for a torsionless grillage with given minimum strength (English)
      0 references
      0 references
      1986
      0 references
      The paper presents the minimum reinforcement solution for the square simply-supported uniformly loaded torsionless grillage, satisfying Rozvany's conditions for minimum moment-volume, for the case where minimum bending strength is specified. The solution only covers a limited range of load magnitudes, but in the development of the moment field the use of lines of load transfer and of the bimoment equation are illustrated. The minimum moment-volume is quite close to that for a simple practical design, which has a relatively unsophisticated moment field and which can cope with any magnitude of load.
      0 references
      minimum reinforcement solution
      0 references
      square simply-supported uniformly loaded torsionless grillage
      0 references
      Rozvany's conditions for minimum moment-volume
      0 references
      minimum bending strength
      0 references

      Identifiers