Optimal design of complex passive-damping systems for vibration control of large structures: an energy-to-peak approach (Q1724279)

From MaRDI portal

!

This is the item page for this Wikibase entity, intended for internal use and editing purposes. Please use the normal view instead:

scientific article; zbMATH DE number 7022515
Language Label Description Also known as
default for all languages
No label defined
    English
    Optimal design of complex passive-damping systems for vibration control of large structures: an energy-to-peak approach
    scientific article; zbMATH DE number 7022515

      Statements

      Optimal design of complex passive-damping systems for vibration control of large structures: an energy-to-peak approach (English)
      0 references
      0 references
      14 February 2019
      0 references
      Summary: We present a new design strategy that makes it possible to synthesize decentralized output-feedback controllers by solving two successive optimization problems with linear matrix inequality (LMI) constraints. In the initial LMI optimization problem, two auxiliary elements are computed: a standard state-feedback controller, which can be taken as a reference in the performance assessment, and a matrix that facilitates a proper definition of the main LMI optimization problem. Next, by solving the second optimization problem, the output-feedback controller is obtained. The proposed strategy extends recent results in static output-feedback control and can be applied to design complex passive-damping systems for vibrational control of large structures. More precisely, by taking advantages of the existing link between fully decentralized velocity-feedback controllers and passive linear dampers, advanced active feedback control strategies can be used to design complex passive-damping systems, which combine the simplicity and robustness of passive control systems with the efficiency of active feedback control. To demonstrate the effectiveness of the proposed approach, a passive-damping system for the seismic protection of a five-story building is designed with excellent results.
      0 references
      passive-damping systems
      0 references
      vibration control
      0 references
      output-feedback controllers
      0 references
      robustness
      0 references
      seismic protection
      0 references

      Identifiers

      0 references
      0 references
      0 references
      0 references
      0 references
      0 references
      0 references
      0 references