A new open loop approach for identifying the initial rotor position of a permanent magnet synchronous motor (Q1794164)
From MaRDI portal
scientific article
Language | Label | Description | Also known as |
---|---|---|---|
English | A new open loop approach for identifying the initial rotor position of a permanent magnet synchronous motor |
scientific article |
Statements
A new open loop approach for identifying the initial rotor position of a permanent magnet synchronous motor (English)
0 references
15 October 2018
0 references
Summary: The precision of initial rotor position detection is critical for the start and running performance of Permanent Magnet Synchronous Motor (PMSM). This work describes a new open loop approach for identifying the initial position of a PMSM with an incremental encoder, even when a constant load torque is being applied. By giving a testing current with high frequency to the stator winding, the initial rotor position of a PMSM can be detected with reasonable accuracy. The rotor almost does not move during the process of identification. The FFT algorithms are used to remove the phase bias effects in identification. Our approach is quicker and simpler than the conventional approaches.
0 references
initial rotor position detection
0 references
permanent magnet synchronous motor
0 references
open loop approach
0 references