No label defined (Q4549249)

From MaRDI portal

!

This is the item page for this Wikibase entity, intended for internal use and editing purposes. Please use the normal view instead:

scientific article; zbMATH DE number 1789938
Language Label Description Also known as
default for all languages
No label defined
    English
    No label defined
    scientific article; zbMATH DE number 1789938

      Statements

      16 June 2003
      0 references
      haemodynamics
      0 references
      partial differential equations
      0 references
      fluid elements
      0 references
      fluid structure interaction
      0 references
      linearization
      0 references
      moving boundary flow
      0 references
      flow of blood
      0 references
      human circulatory system
      0 references
      electrical circuit analogue
      0 references
      lumped parameter model
      0 references
      0 references
      The author discusses the development of mathematical models for the flow of blood in the human circulatory system. By necessity, such a model of a living system must include several simplifications, ignore some factors, and make several assumptions. This is not a simple fluid flow problem with a routine application of Navier-Stoke equations. There are several chemical reactions going on, there is a coupling between the fluid flow and the motion of the vessel wall. Moreover, the material of the vessel is not easily described. It would be a good experimental project to come up with even approximate constitutive equations for the wall region of a human artery. Thus we have a moving boundary type of flow, with mechanical interactions between the boundary and the fluid not really defined. The resulting compromise ignores nonlinearities by making the ``small displacement assumption''. The author uses a compromise between the Eulerian and Lagrangian description of the flow. A geomerically conforming finite element grid is reconstructed at each finite step i.e. at each time interval of the flow. A linear variation accompanies each such ``small'' time step. An electrical circuit analogue describes the flow based on a lumped parameter model. Probably the next step shall be to coordinate the measurements predicted by this model by using a computerized feedback control identification loop, thus clinically checking the validity of these models of cardiovascular systems, and perhaps revising some assumptions. For the entire collection see [Zbl 0993.00023].
      0 references

      Identifiers

      0 references
      0 references
      0 references
      0 references
      0 references
      0 references
      0 references