Melting from heat sources flush mounted on a conducting vertical wall (Q4952201)

From MaRDI portal

!

This is the item page for this Wikibase entity, intended for internal use and editing purposes. Please use the normal view instead:

scientific article; zbMATH DE number 1443291
Language Label Description Also known as
default for all languages
No label defined
    English
    Melting from heat sources flush mounted on a conducting vertical wall
    scientific article; zbMATH DE number 1443291

      Statements

      Melting from heat sources flush mounted on a conducting vertical wall (English)
      0 references
      0 references
      0 references
      2 December 2002
      0 references
      melting control
      0 references
      melting optimization
      0 references
      natural-convection-dominated melting
      0 references
      discretely heated rectangular enclocures
      0 references
      hybrid difference scheme
      0 references
      SIMPLEC algorithm
      0 references
      velocity-pressure coupling
      0 references
      line-by-line tridiagonal matrix algorithm
      0 references
      The authors carry out a numerical study of a natural-convection-dominated melting inside discretely heated rectangular enclocures. This problem has important practical applications in the design and operation of thermal energy storage units, and in the cooling of electric equipment. The governing, equations are solved numerically using the finite difference method. To avoid numerical instability, the advection terms are discretized with a hybrid difference scheme, and the SIMPLEC algorithm is adopted for the velocity-pressure coupling. The set of linearized equations is solved iteratively by a line-by-line tridiagonal matrix algorithm by sweeping the cavity from left to right. The results are tested experimentally. The authors show indisputable benefits of discrete heating over uniform heating for optimizing the melting process. For enclosures of high aspect ratios \((A\gtrsim 4)\), the authors obtain configurations leading to well-controlled heat source temperatures and long melting times. However, for cavities of lower aspect ratio \((A\lesssim 4)\), the source span \(\eta\) is the most influencing parameter on the melting time. All source configurations are bounded by two limits: a lower limit corresponding to a line heat source distribution, and an upper limit corresponding to a uniformly heated wall section.
      0 references

      Identifiers

      0 references
      0 references
      0 references
      0 references
      0 references
      0 references