Simultaneous recovery of attenuation and source density in SPECT (Q6042375)
From MaRDI portal
scientific article; zbMATH DE number 7684040
Language | Label | Description | Also known as |
---|---|---|---|
English | Simultaneous recovery of attenuation and source density in SPECT |
scientific article; zbMATH DE number 7684040 |
Statements
Simultaneous recovery of attenuation and source density in SPECT (English)
0 references
10 May 2023
0 references
The identification problem of Single Photon Emission Computed Tomography (SPECT) in two dimensions seeks to recover both attenuation \(a\) and radiation source density \(f\) in the attenuated Radon transform. This is not possible in general, but it is shown here that it is possible if \(a\) is piecewise constant and \(f\) piecewise \(C^2\) over domains with real analytic boundaries possibly having corners, plus a certain non-cancellation condition. Numerical examples show that unique reconstruction of \(a\) and \(f\) may still be possible even if the non-cancellation condition fails.
0 references
SPECT
0 references
attenuated Radon transform
0 references
reconstruction
0 references
0 references
0 references