Evaluating registrations of serial sections with distortions of the ground truths. Supplemental data (Q6702302)

From MaRDI portal





Dataset published at Zenodo repository.
Language Label Description Also known as
default for all languages
No label defined
    English
    Evaluating registrations of serial sections with distortions of the ground truths. Supplemental data
    Dataset published at Zenodo repository.

      Statements

      0 references
      Evaluating Registrations of Serial Sections With Distortions of the Ground Truths This is the supplemental data for our paper on how to benchmark registrations of serial sections with ground truths. The files are namedas follows: *_challenge.7z: local distortions and global rigid transformations applied, the input for the benchmark we used. Use this to test your rigid and non-rigid methods. *_local-only.7z: only local distortions applied. *_local-DIST.7z: the distortion maps for local distortions. *_SURF-rigid.7z:local distortions and global rigid transformations applied, rigid transformations undone with SURF-based rigid-only method. Local distortions remain. Use this if your method does not cope well with large rigid transformations. _*vis.7z: visualizations of distortions. _rigid_ground.7z: the real rigid transformations used in the global phase. *_ground.7z: the ground truth. All data fit each other, no distortions. Use this to compare your registration result to it. There are three main modalities and one further, as a reference: CT_*: CT data, a rabbit lung, 600 images.(In ground truth, and local distortions, and global transformationswe supply more images that went into the benchmark, 50 more from both beginning and end.) EM_*: an EM serial block-face (SBF-SEM) data set of adult mouse lung, 1000 images. (EM ground truth is individually normalized, see paper.) LS_*: a lung from the light sheet microscopy from a male 24 week-old rat, 300 images. (LS ground truth is individually normalized, too.) REAL_*: a region from real serial sections from a rabbit lung, 2 images. We also supply elastix parameter files. A preprint has been uploaded to arXiv. The definite version is available from IEEE. The source code of the distorter is available from GitHub.
      0 references
      20 November 2020
      0 references
      0 references
      0 references
      0 references
      0 references
      0 references
      0 references
      0 references

      Identifiers

      0 references