A mathematical model of drug dynamics in an electroporated tissue
cell membranedrug deliveryelectric pulseelectroporationmass transferpore densityreversibly and irreversibly electroporated cells
Nonlinear boundary value problems for ordinary differential equations (34B15) Qualitative investigation and simulation of ordinary differential equation models (34C60) Cell biology (92C37) Kinetics in biochemical problems (pharmacokinetics, enzyme kinetics, etc.) (92C45) Medical applications (general) (92C50)
The model considered here concerns a spherical (i.e., disk-like) biological tissue to which an electric field is applied to open up the pores of cell membranes to facilitate the entrance of a drug into the cells contained in the tissue. The phenomenon is called electroporation. Depending on the strength of the voltage pulse, one distinguishes between reversible electroporation, i.e., lower voltage with subsequent membrane resealing, desirable in normal drug administration, and irreversible electroporation, i.e., higher voltage resulting in permanently open pores, a case desirable in chemotherapy with the aim of killing the pertinent cells. The state of the system modelling the drug uptake is described by differential equations for the temporal development of the drug concentrations \(C_E\) in extracellular space and \(C_{RE}\), \(C_{IRE}\) inside the cells, for the reversible and the irreversible case, resp. Numerical results show excellent coincidence with analytical results achieved for special values of space coordinates. As it turns out, a minimum of about 100\,V/cm is required to initiate electroporation. The graphical plots deal with varied values of the drug permeability \(P\), the electric field \(E\), and the duration \(t_{ep}\) of the electroporation. Finally, a sensitivity analysis is carried out.
- Mass transfer model for drug delivery in tissue cells with reversible electroporation
- ``Classical electropermeabilization modeling at the cell scale
- Comparison and calibration of different electroporation models. Application to rabbit livers experiments
- Conducting and permeable states of cell membrane submitted to high voltage pulses: mathematical and numerical studies validated by the experiments
- Influence of electric pulse characteristics on the cellular internalization of chemotherapeutic drugs and cell survival fraction in electroporated and vasoconstricted cancer tissues using boundary element techniques
- In-silico study about the influence of electroporation parameters on the chemotherapeutic drug transport in cancer tissues using the meshless method of approximate particular solutions
- scientific article; zbMATH DE number 5802062 (Why is no real title available?)
- Comparison and calibration of different electroporation models. Application to rabbit livers experiments
- Resistive heating and electropermeabilization of skin tissue during in vivo electroporation: a coupled nonlinear finite element model
- Dynamics and control of the two-pulse protocol in electroporation: numerical exploration
- Influence of electric pulse characteristics on the cellular internalization of chemotherapeutic drugs and cell survival fraction in electroporated and vasoconstricted cancer tissues using boundary element techniques
- Multiscale modelling of fluid transport in vascular tumours subjected to electrophoresis anticancer therapies
- Control of pore radius regulation for electroporation-based drug delivery
- Mass transfer model for drug delivery in tissue cells with reversible electroporation
This page was built for publication: A mathematical model of drug dynamics in an electroporated tissue
Report a bug (only for logged in users!)Click here to report a bug for this page (MaRDI item Q2092236)