Constrained total variation based three-dimension single particle reconstruction in cryogenic electron microscopy
From MaRDI portal
Publication:2211747
Recommendations
- Toward Single Particle Reconstruction without Particle Picking: Breaking the Detection Limit
- A wavelet based alternative iteration method for the orientation refinement of cryo-electron microscopy 3D reconstruction
- Rapid solution of the cryo-EM reconstruction problem by frequency marching
- Cryo-electron microscopy data denoising based on the generalized digitized total variation method
- Orientation determination of cryo-EM images using least unsquared deviations
Cites work
- A first-order primal-dual algorithm for convex problems with applications to imaging
- Accelerating the Nonuniform Fast Fourier Transform
- Adaptive total variation image deblurring: a majorization-minimization approach
- An Exact and Fast Computation of Discrete Fourier Transform for Polar and Spherical Grid
- Analysis of Discrete Ill-Posed Problems by Means of the L-Curve
- Convex optimization theory.
- Generalized Cross-Validation as a Method for Choosing a Good Ridge Parameter
- scientific article; zbMATH DE number 3876486 (Why is no real title available?)
- scientific article; zbMATH DE number 1375199 (Why is no real title available?)
- Image recovery via total variation minimization and related problems
- Nonlinear total variation based noise removal algorithms
- Nonuniform fast fourier transforms using min-max interpolation
- Orientation determination of cryo-EM images using least unsquared deviations
- Toeplitz-based iterative image reconstruction for MRI with correction for magnetic field inhomogeneity
- Variational Bayesian Blind Deconvolution Using a Total Variation Prior
- Viewing angle classification of cryo-electron microscopy images using eigenvectors
Cited in
(11)- Iterative hybrid regularization for extremely noisy full models in single particle analysis
- Volumetric restrictions in single particle 3DEM reconstruction
- A methodology for deblurring and recovering conformational states of biomolecular complexes from single particle electron microscopy
- Cryo-electron microscopy data denoising based on the generalized digitized total variation method
- Cryogenic electron tomography reconstructions from phaseless data
- Special issue on cryo-electron microscopy and inverse problems
- Wavelet frame based algorithm for 3D reconstruction in electron microscopy
- Research in Computational Molecular Biology
- Toward Single Particle Reconstruction without Particle Picking: Breaking the Detection Limit
- Sparse approximations of protein structure from noisy random projections
- Model calculations for joint pattern recognition and signal reconstruction in cryo electron microscopy
This page was built for publication: Constrained total variation based three-dimension single particle reconstruction in cryogenic electron microscopy