Toward Single Particle Reconstruction without Particle Picking: Breaking the Detection Limit
From MaRDI portal
Abstract: Single-particle cryo-electron microscopy (cryo-EM) has recently joined X-ray crystallography and NMR spectroscopy as a high-resolution structural method to resolve biological macromolecules. In a cryo-EM experiment, the microscope produces images called micrographs. Projections of the molecule of interest are embedded in the micrographs at unknown locations, and under unknown viewing directions. Standard imaging techniques first locate these projections (detection) and then reconstruct the 3-D structure from them. Unfortunately, high noise levels hinder detection. When reliable detection is rendered impossible, the standard techniques fail. This is a problem, especially for small molecules. In this paper, we pursue a radically different approach: we contend that the structure could, in principle, be reconstructed directly from the micrographs, without intermediate detection. The aim is to bring small molecules within reach for cryo-EM. To this end, we design an autocorrelation analysis technique that allows to go directly from the micrographs to the sought structures. This involves only one pass over the micrographs, allowing online, streaming processing for large experiments. We show numerical results and discuss challenges that lay ahead to turn this proof-of-concept into a complementary approach to state-of-the-art algorithms.
Recommendations
- Rapid solution of the cryo-EM reconstruction problem by frequency marching
- Multi-target detection with application to cryo-electron microscopy
- Three-dimensional structure determination from common lines in cryo-EM by eigenvectors and semidefinite programming
- Mathematics for cryo-electron microscopy
- Constrained total variation based three-dimension single particle reconstruction in cryogenic electron microscopy
Cites work
- Estimation under group actions: recovering orbits from invariants
- Higher criticism for detecting sparse heterogeneous mixtures.
- Method of moments for 3D single particle \textit{ab initio} modeling with non-uniform distribution of viewing angles
- Multi-Target Detection With an Arbitrary Spacing Distribution
- Multi-reference alignment in high dimensions: sample complexity and phase transition
- Multi-target detection with application to cryo-electron microscopy
- Multi-target detection with rotations
- Multireference Alignment Is Easier With an Aperiodic Translation Distribution
- Non-unique games over compact groups and orientation estimation in cryo-EM
- Prolate Spheroidal Wave Functions, Fourier Analysis and Uncertainty - IV: Extensions to Many Dimensions; Generalized Prolate Spheroidal Functions
- Steerable principal components for space-frequency localized images
- The Efficient Generation of Random Orthogonal Matrices with an Application to Condition Estimators
- The Steerable Graph Laplacian and its Application to Filtering Image Datasets
- The mathematics of computerized tomography
- The sample complexity of multireference alignment
Cited in
(21)- Constrained total variation based three-dimension single particle reconstruction in cryogenic electron microscopy
- A Bayesian approach to initial model inference in cryo-electron microscopy
- Multi-target detection with application to cryo-electron microscopy
- Rapid solution of the cryo-EM reconstruction problem by frequency marching
- A max-cut approach to heterogeneity in cryo-electron microscopy
- \(\gamma\)-SUP: a clustering algorithm for cryo-electron microscopy images of asymmetric particles
- Orbit recovery for band-limited functions
- Swarm optimization as a consensus technique for electron microscopy initial volume
- Unsupervised particle sorting for high-resolution single-particle cryo-EM
- Subspace method of moments for \textit{ab initio} 3-D single particle cryo-EM reconstruction
- Orthogonal Matrix Retrieval with Spatial Consensus for 3D Unknown View Tomography
- Research in Computational Molecular Biology
- An automatic particle picking method based on generative adversarial network
- Cryo-EM reconstruction of continuous heterogeneity by Laplacian spectral volumes
- Cryo-electron microscopy data denoising based on the generalized digitized total variation method
- Reconstruction from limited single-particle diffraction data via simultaneous determination of state, orientation intensity, and phase
- Model calculations for joint pattern recognition and signal reconstruction in cryo electron microscopy
- Multi-target detection with rotations
- A methodology for deblurring and recovering conformational states of biomolecular complexes from single particle electron microscopy
- Mathematics for cryo-electron microscopy
- Iterative hybrid regularization for extremely noisy full models in single particle analysis
This page was built for publication: Toward Single Particle Reconstruction without Particle Picking: Breaking the Detection Limit
Report a bug (only for logged in users!)Click here to report a bug for this page (MaRDI item Q6113268)