Algorithm for the reconstruction of dynamic objects in CT-scanning using optical flow
From MaRDI portal
Publication:2332760
Abstract: Computed Tomography is a powerful imaging technique that allows non-destructive visualization of the interior of physical objects in different scientific areas. In traditional reconstruction techniques the object of interest is mostly considered to be static, which gives artefacts if the object is moving during the data acquisition. In this paper we present a method that, given only scan results of multiple successive scans, can estimate the motion and correct the CT-images for this motion assuming that the motion field is smooth over the complete domain using optical flow. The proposed method is validated on simulated scan data. The main contribution is that we show we can use the optical flow technique from imaging to correct CT-scan images for motion.
Recommendations
- Reconstruction of dynamic objects with affine deformations in computerized tomography
- Motion compensation strategies in tomography
- Dynamic procedures of image reconstruction from projections (computer tomography)
- Efficient algorithms for linear dynamic inverse problems with known motion
- Reduced motion artifacts in medical imaging by adaptive spatio-temporal reconstruction
Cites work
- A lagged diffusivity method for computing total variation regularized fluid flow
- A proof of convergence of the Horn-Schunck optical flow algorithm in arbitrary dimension
- An Inexact Newton--Krylov Algorithm for Constrained Diffeomorphic Image Registration
- Approximate inverse for linear and some nonlinear problems
- DART: A Practical Reconstruction Algorithm for Discrete Tomography
- Efficient algorithms for linear dynamic inverse problems with known motion
- Lucas/Kanade meets Horn/Schunck: combining local and global optic flow methods
- Recent computational developments in Krylov subspace methods for linear systems
- Region-Based Iterative Reconstruction of Structurally Changing Objects in CT
- The mathematics of computerized tomography
- Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction?
Cited in
(5)- Reconstruction of dynamic objects with affine deformations in computerized tomography
- Dynamic cone-beam reconstruction for perfusion computed tomography.
- A motion artefact study and locally deforming objects in computerized tomography
- Multi-domain regularization based computed tomography for high-speed rotation objects
- A general scheme for velocity tomography
This page was built for publication: Algorithm for the reconstruction of dynamic objects in CT-scanning using optical flow
Report a bug (only for logged in users!)Click here to report a bug for this page (MaRDI item Q2332760)