Effect of body acceleration on unsteady pulsatile flow of non-Newtonian fluid through a stenosed artery

From MaRDI portal
Publication:2381378

DOI10.1016/j.amc.2006.11.139zbMath1125.76079OpenAlexW1998841234MaRDI QIDQ2381378

Norsarahaida Amin, Arabinda Mandal, Prashanta Kumar Mandal, Santabrata Chakravarty

Publication date: 17 September 2007

Published in: Applied Mathematics and Computation (Search for Journal in Brave)

Full work available at URL: https://doi.org/10.1016/j.amc.2006.11.139



Related Items

Role of a structural parameter in modelling blood flow through a tapering channel, Computational analysis of blood flow through stenosed artery under the influence of body acceleration using Shishkin mesh, Unsteady blood flow through a tapered stenotic artery using sisko model, Pulsatile flow of blood in a vessel using an Oldroyd-B fluid, The micropolar fluid model for blood flow through a tapered artery with a stenosis, Casson rheological flow model in an inclined stenosed artery with non-Darcian porous medium and quadratic thermal convection, UNSTEADY TWO-LAYERED BLOOD FLOW THROUGH A -SHAPED STENOSED ARTERY USING THE GENERALIZED OLDROYD-B FLUID MODEL, Nonlinear fluid models for biofluid flow in constricted blood vessels under body accelerations: a comparative study, Numerical simulation of pulsatile flow of blood in a porous-saturated overlapping stenosed artery, An unsteady peristaltic transport phenomenon of non-Newtonian fluid -- a generalised approach, Pulsatile flow of blood using a modified second-grade fluid model, An unsteady flow of magnetic nanoparticles as drug carrier suspended in micropolar fluid through a porous tapered arterial stenosis under non-uniform magnetic field and periodic body acceleration, Computational biomedical simulations of hybrid nanoparticles on unsteady blood hemodynamics in a stenotic artery, Time dependent non-Newtonian nano-fluid (blood) flow in w-shape stenosed channel; with curvature effects, Comparative analysis of mathematical models for blood flow in tapered constricted arteries, EFFECT OF ASYMMETRY AND ROUGHNESS OF STENOSIS ON NON-NEWTONIAN FLOW PAST AN ARTERIAL SEGMENT, An implicit approach to the micropolar fluid model of blood flow under the effect of body acceleration, Perturbation analysis for pulsatile flow of Carreau fluid through tapered stenotic arteries, Blood flow analysis in tapered stenosed arteries with the influence of heat and mass transfer, Unsteady response of non-Newtonian blood flow through a stenosed artery in magnetic field, Analysis of dynamics variation against thixotropic parameter’s preferential range, Unnamed Item, Influence of electromagnetic field and thermal radiation on pulsatile blood flow with nanoparticles in a constricted porous artery



Cites Work