Synergism of spectra averaging and extrapolation for quantification of in vivo MRS time signals encoded from the ovary
From MaRDI portal
Publication:2399213
DOI10.1007/s10910-016-0728-2zbMath1372.92048OpenAlexW2579680521WikidataQ59611502 ScholiaQ59611502MaRDI QIDQ2399213
Publication date: 22 August 2017
Published in: Journal of Mathematical Chemistry (Search for Journal in Brave)
Full work available at URL: https://doi.org/10.1007/s10910-016-0728-2
fast Padé transformmagnetic resonance spectroscopymathematical optimizationovarian cancer diagnostics
Related Items (8)
Encoded in vivo time signals from the ovary in magnetic resonance spectroscopy: poles and zeros as the cornerstone for stability of response functions of systems to external perturbations ⋮ Visualizing hidden components of envelopes non-parametrically in magnetic resonance spectroscopy: phosphocholine, a breast cancer biomarker ⋮ Review of recent applications of the conventional and derivative fast Padé transform for magnetic resonance spectroscopy ⋮ Robust identification of the cancer biomarker phosphocholine through partitioned envelopes in noisy magnetic resonance spectroscopic data by the non-parametric fast Padé transform ⋮ Explicit extraction of absorption peak positions, widths and heights using higher order derivatives of total shape spectra by nonparametric processing of time signals as complex damped multi-exponentials ⋮ High-resolution at 3\,T for in vivo derivative NMR spectroscopy in medical diagnostics of ovarian tumor: exact quantification by shape estimations ⋮ Automatic self-correcting in signal processing for magnetic resonance spectroscopy: noise reduction, resolution improvement and splitting overlapped peaks ⋮ In vitro proton magnetic resonance spectroscopy at 14T for benign and malignant ovary. I: Signal processing by the nonparametric fast Padé transform
Cites Work
- Unnamed Item
- The fast Padé transform for noisy magnetic resonance spectroscopic data from the prostate: potential contribution to individualized prostate cancer care
- How the fast Padé transform handles noise for MRS data from the ovary: importance for ovarian cancer diagnostics
- Mathematically-optimized magnetic resonance spectroscopy in breast cancer diagnostics: implications for personalized cancer medicine
- Quantification by the fast Padé transform of magnetic resonance spectroscopic data encoded at 1.5 T: implications for brain tumor diagnostics
- Improving the diagnostic yield of magnetic resonance spectroscopy for pediatric brain tumors through mathematical optimization
- Padé optimization of noise-corrupted magnetic resonance spectroscopic time signals from fibroadenoma of the breast
- Iterative averaging of spectra as a powerful way of suppressing spurious resonances in signal processing
- In vivo magnetic resonance spectroscopy for ovarian cancer diagnostics: quantification by the fast Padé transform
- The potential for practical improvements in cancer diagnostics by mathematically-optimized magnetic resonance spectroscopy
- Mathematical optimization of in vivo NMR chemistry through the fast Padé transform: Potential relevance for early breast cancer detection by magnetic resonance spectroscopy
- Mathematical modeling of an NMR chemistry problem in ovarian cancer diagnostics
- Magnetic resonance spectroscopy with high-resolution and exact quantification in the presence of noise for improving ovarian cancer detection
- The general concept of signal-noise separation (SNS): mathematical aspects and implementation in magnetic resonance spectroscopy
- Exact quantification of time signals from magnetic resonance spectroscopy by the fast Padé transform with applications to breast cancer diagnostics
- Unequivocal resolution of multiplets in MR spectra for prostate cancer diagnostics achieved by the fast Padé transform
- Automatic self-correcting in signal processing for magnetic resonance spectroscopy: noise reduction, resolution improvement and splitting overlapped peaks
- Resolution enhancement as a key step towards clinical implementation of Padé-optimized magnetic resonance spectroscopy for diagnostic oncology
This page was built for publication: Synergism of spectra averaging and extrapolation for quantification of in vivo MRS time signals encoded from the ovary