Publication:3768787





Consider the open-loop system \(\Sigma_ 0\) \(x=A^ 0_ 1x+B^ 0_ 1u+A^ 0_ 3f,\quad \dot f=A_ 2f\) \[ y=C^ 0_ 1x+C^ 0_ 2f,\quad z=D^ 0_ 1x+D^ 0_ 2f \] and the dynamic compensator \(\Sigma_ p\) \[ x_ c=A_ cx_ c+B_ cy,\quad u=F_ cx_ c+Fy. \] Assume that \(\Sigma_ 0\) and \(\Sigma_ p\) satisfy the internal model principle. First, a formula of estimating the scope of change of spectrum is given. Then several upper-bound estimates of tolerable perturbations for open-loop systems with respect to amplitude and \(\| \cdot \|_{\infty}\) are obtained. An example is given for illustration.