Modelling of an oesophageal electrode for cardiac function tomography
Summary: There is a need in critical care units for continuous cardiopulmonary monitoring techniques. ECG gated electrical impedance tomography is able to localize the impedance variations occurring during the cardiac cycle. This method is a safe, inexpensive and potentially fast technique for cardiac output imaging but the spatial resolution is presently low, particularly for central locations such as the heart. Many parameters including noise deteriorate the reconstruction result. One of the main obstacles in cardiac imaging at the heart location is the high impedance of lungs and muscles on the dorsal and posterior side of body. We investigate improvements of the measurement and initial conductivity estimation of the internal electrode by modelling an internal electrode inside the esophagus. We consider 16 electrodes connected around a cylindrical mesh. With the random noise level set near 0.05\% of the signal we evaluated the Graz consensus reconstruction algorithm for electrical impedance tomography. The modelling and simulation results showed that the quality of the target in reconstructed images was improved by up to 5 times for amplitude response, position error, resolution, shape deformation and ringing effects with perturbations located in cardiac related positions when using an internal electrode.
- A local region of interest imaging method for electrical impedance tomography with internal electrodes
- Monitoring lungs with electrical impedance tomography
- Electrode Modelling in Electrical Impedance Tomography
- Fine-tuning electrode information in electrical impedance tomography
- scientific article; zbMATH DE number 1490055
- \(L^1\) regularization method in electrical impedance tomography by using the \(L^1\)-curve (Pareto frontier curve)
- Analysis of Discrete Ill-Posed Problems by Means of the L-Curve
- Dynamic inverse obstacle problems with electrical impedance tomography
- Electrical Impedance Tomography
- scientific article; zbMATH DE number 3227378 (Why is no real title available?)
- NETGEN: An advancing front 2D/3D-mesh generator based on abstract rules
- RECONSTRUCTION OF DOMAIN BOUNDARY AND CONDUCTIVITY IN ELECTRICAL IMPEDANCE TOMOGRAPHY USING THE APPROXIMATION ERROR APPROACH
- Statistical inverse problems: discretization, model reduction and inverse crimes
- The Inverse Conductivity Problem with an Imperfectly Known Boundary
This page was built for publication: Modelling of an oesophageal electrode for cardiac function tomography
Report a bug (only for logged in users!)Click here to report a bug for this page (MaRDI item Q428272)