An analysis of blocking phenomena in Discrete Event Systems (DES) with corrective and/or Preventive Maintenance Schedules (PMS) is addressed. It is shown that stopping activities in DES is not necessary when one or more machines are in corrective and/or PMS for some DES structures with reentrant flow-lines. Deadlock-free dispatching rules are derived by circular wait analysis for possible deadlock situations in the systems with PMS. This is accomplished by integrating a finite state automata supervision between two subsystems; the reentrant flow-line (RF) system structure controlled by the DES matrix formulation and the DES system with the failure and preventive dynamics that acts as a disturbance in the first DES. For the entire collection see [Zbl 1030.00023].