A numerical investigation of flows of shear-thinning fluids with applications to blood rheology
DOI10.1002/(SICI)1097-0363(20000415)32:7%3C863::AID-FLD997%3E3.0.CO;2-PzbMATH Open0974.76046OpenAlexW1990637800MaRDI QIDQ4484977FDOQ4484977
Authors: J. Hron, Josef Málek, S. Turek
Publication date: 5 June 2000
Full work available at URL: https://doi.org/10.1002/(sici)1097-0363(20000415)32:7%3C863::aid-fld997%3E3.0.co;2-p
Recommendations
- Pulsatile flow of a shear-thinning model for blood through a two-dimensional stenosed channel
- Numerical simulation of physiologically relevant pulsatile flow of blood with shear-rate-dependent viscosity in a stenosed blood vessel
- Effect of asymmetry and roughness of stenosis on non-Newtonian flow past an arterial segment
- Numerical study of shear-dependent non-Newtonian fluids in compliant vessels
- Numerical study of the unsteady flow of non-Newtonian fluid through differently shaped arterial stenoses
stenosismultigrid solverpower-law fluidfriction factorshear-thinning fluidpulsatile flowscorrugated channelsnormal stress amplitudeprojection solver
Non-Newtonian fluids (76A05) Finite element methods applied to problems in fluid mechanics (76M10) Physiological flows (76Z05) Biomechanics (92C10)
Cites Work
Cited In (10)
- Numerical simulation of blood flow in abdominal aortic aneurysms: effects of blood shear-thinning and viscoelastic properties
- Micro-macro simulations of a shear-thinning viscoelastic kinetic model: applications to blood flow
- Pulsatile flow of blood in a vessel using an Oldroyd-B fluid
- Distributed control for a class of non-Newtonian fluids
- Numerical study of fluid flow through double bell‐shaped constrictions in a tube
- Pulsatile flow of blood using a modified second-grade fluid model
- Numerical study of the effect of blockage ratio in forced convection confined flows of shear-thinning fluids
- A fast numerical approach for the simulation of highly viscous non-isothermal non-Newtonian fluids
- Effect of real and whole blood rheology on flow through an axisymmetric stenosed artery
- Time‐dependent finite element simulations of a shear‐thinning viscoelastic fluid with application to blood flow
Uses Software
This page was built for publication: A numerical investigation of flows of shear-thinning fluids with applications to blood rheology
Report a bug (only for logged in users!)Click here to report a bug for this page (MaRDI item Q4484977)