A model for micropolar fluid film mechanism with reference to human joints (Q1100062)

From MaRDI portal
scientific article
Language Label Description Also known as
English
A model for micropolar fluid film mechanism with reference to human joints
scientific article

    Statements

    A model for micropolar fluid film mechanism with reference to human joints (English)
    0 references
    0 references
    1988
    0 references
    This paper analyzes the variation of pressure and load capacity with reference to load bearing human joints by introducing a continuously varying porosity model for lower plate instead of usual uniform mono or multi-layered models studied so far. A micropolar fluid film is taken as a lubricant. By suitable choice of non-dimensional porosity variation parameter \({\bar \alpha}\); it is shown that trends of variations are fairly in agreement with those recorded in earlier investigations.