Towards monitoring critical microscopic parameters for electropermeabilization
From MaRDI portal
Homogenization in context of PDEs; PDEs in media with periodic structure (35B27) Dependence of solutions to PDEs on initial and/or boundary data and/or on parameters of PDEs (35B30) PDEs in connection with optics and electromagnetic theory (35Q60) PDEs in connection with biology, chemistry and other natural sciences (35Q92) Inverse problems for PDEs (35R30)
Abstract: Electropermeabilization is a clinical technique in cancer treatment to locally stimulate the cell metabolism. It is based on electrical fields that change the properties of the cell membrane. With that, cancer treatment can reach the cell more easily. Electropermeabilization occurs only with accurate dosage of the electrical field. For applications, a monitoring for the amount of electropermeabilization is needed. It is a first step to image the macroscopic electrical field during the process. Nevertheless, this is not complete, because electropermeabilization depends on critical individual properties of the cells such as their curvature. From the macroscopic field, one cannot directly infer that microscopic state. In this article, we study effective parameters in a homogenization model as the next step to monitor the microscopic properties in clinical practice. We start from a physiological cell model for electropermeabilization and analyze its well-posedness. For a dynamical homogenization scheme, we prove convergence and then analyze the effective parameters, which can be found by macroscopic imaging methods. We demonstrate numerically the sensitivity of these effective parameters to critical microscopic parameters governing electropermeabilization. This opens the door to solve the inverse problem of rreconstructing these parameters.
Recommendations
- ``Classical electropermeabilization modeling at the cell scale
- Cell scale modeling of electropermeabilization by periodic pulses
- Conducting and permeable states of cell membrane submitted to high voltage pulses: mathematical and numerical studies validated by the experiments
- Numerical modelling challenges for clinical electroporation ablation technique of liver tumors
- Comparison and calibration of different electroporation models. Application to rabbit livers experiments
Cites work
- A Simple Mesh Generator in MATLAB
- EVOLUTION AND MEMORY EFFECTS IN THE HOMOGENIZATION LIMIT FOR ELECTRICAL CONDUCTION IN BIOLOGICAL TISSUES
- Magnetic resonance electrical impedance tomography (MREIT)
- Ordinary differential equations. An introduction to nonlinear analysis. Transl. from the German by Gerhard Metzen
- Spectroscopic imaging of a dilute cell suspension
- Uniqueness and convergence of conductivity image reconstruction in magnetic resonance electrical impedance tomography
- ``Classical electropermeabilization modeling at the cell scale
Cited in
(10)- ``Classical electropermeabilization modeling at the cell scale
- Optimal placement of electrodes in an electroporation process
- Multiple traces formulation and semi-implicit scheme for modelling biological cells under electrical stimulation
- Derivation of cable equation by multiscale analysis for a model of myelinated axons
- Cell scale modeling of electropermeabilization by periodic pulses
- Numerical modelling challenges for clinical electroporation ablation technique of liver tumors
- Unfolding homogenization method applied to physiological and phenomenological bidomain models in electrocardiology
- Cell electropermeabilization modeling via multiple traces formulation and time semi-implicit multistep coupling
- On the Formation of Glass Microelectrodes
- A Voronoi interface approach to cell aggregate electropermeabilization
This page was built for publication: Towards monitoring critical microscopic parameters for electropermeabilization
Report a bug (only for logged in users!)Click here to report a bug for this page (MaRDI item Q2833053)