Modelling of an oesophageal electrode for cardiac function tomography (Q428272): Difference between revisions

From MaRDI portal
Importer (talk | contribs)
Created a new Item
 
ReferenceBot (talk | contribs)
Changed an Item
 
(8 intermediate revisions by 7 users not shown)
Property / author
 
Property / author: Alistair McEwan / rank
Normal rank
 
Property / author
 
Property / author: Alistair McEwan / rank
 
Normal rank
Property / review text
 
Summary: There is a need in critical care units for continuous cardiopulmonary monitoring techniques. ECG gated electrical impedance tomography is able to localize the impedance variations occurring during the cardiac cycle. This method is a safe, inexpensive and potentially fast technique for cardiac output imaging but the spatial resolution is presently low, particularly for central locations such as the heart. Many parameters including noise deteriorate the reconstruction result. One of the main obstacles in cardiac imaging at the heart location is the high impedance of lungs and muscles on the dorsal and posterior side of body. We investigate improvements of the measurement and initial conductivity estimation of the internal electrode by modelling an internal electrode inside the esophagus. We consider 16 electrodes connected around a cylindrical mesh. With the random noise level set near 0.05\% of the signal we evaluated the Graz consensus reconstruction algorithm for electrical impedance tomography. The modelling and simulation results showed that the quality of the target in reconstructed images was improved by up to 5 times for amplitude response, position error, resolution, shape deformation and ringing effects with perturbations located in cardiac related positions when using an internal electrode.
Property / review text: Summary: There is a need in critical care units for continuous cardiopulmonary monitoring techniques. ECG gated electrical impedance tomography is able to localize the impedance variations occurring during the cardiac cycle. This method is a safe, inexpensive and potentially fast technique for cardiac output imaging but the spatial resolution is presently low, particularly for central locations such as the heart. Many parameters including noise deteriorate the reconstruction result. One of the main obstacles in cardiac imaging at the heart location is the high impedance of lungs and muscles on the dorsal and posterior side of body. We investigate improvements of the measurement and initial conductivity estimation of the internal electrode by modelling an internal electrode inside the esophagus. We consider 16 electrodes connected around a cylindrical mesh. With the random noise level set near 0.05\% of the signal we evaluated the Graz consensus reconstruction algorithm for electrical impedance tomography. The modelling and simulation results showed that the quality of the target in reconstructed images was improved by up to 5 times for amplitude response, position error, resolution, shape deformation and ringing effects with perturbations located in cardiac related positions when using an internal electrode. / rank
 
Normal rank
Property / Mathematics Subject Classification ID
 
Property / Mathematics Subject Classification ID: 92C55 / rank
 
Normal rank
Property / Mathematics Subject Classification ID
 
Property / Mathematics Subject Classification ID: 92C50 / rank
 
Normal rank
Property / Mathematics Subject Classification ID
 
Property / Mathematics Subject Classification ID: 92C05 / rank
 
Normal rank
Property / Mathematics Subject Classification ID
 
Property / Mathematics Subject Classification ID: 92-08 / rank
 
Normal rank
Property / zbMATH DE Number
 
Property / zbMATH DE Number: 6047853 / rank
 
Normal rank
Property / Wikidata QID
 
Property / Wikidata QID: Q42566371 / rank
 
Normal rank
Property / describes a project that uses
 
Property / describes a project that uses: EIDORS / rank
 
Normal rank
Property / MaRDI profile type
 
Property / MaRDI profile type: MaRDI publication profile / rank
 
Normal rank
Property / full work available at URL
 
Property / full work available at URL: https://doi.org/10.1155/2012/585786 / rank
 
Normal rank
Property / OpenAlex ID
 
Property / OpenAlex ID: W2005078182 / rank
 
Normal rank
Property / cites work
 
Property / cites work: Statistical inverse problems: discretization, model reduction and inverse crimes / rank
 
Normal rank
Property / cites work
 
Property / cites work: The Inverse Conductivity Problem with an Imperfectly Known Boundary / rank
 
Normal rank
Property / cites work
 
Property / cites work: RECONSTRUCTION OF DOMAIN BOUNDARY AND CONDUCTIVITY IN ELECTRICAL IMPEDANCE TOMOGRAPHY USING THE APPROXIMATION ERROR APPROACH / rank
 
Normal rank
Property / cites work
 
Property / cites work: \(L^1\) regularization method in electrical impedance tomography by using the \(L^1\)-curve (Pareto frontier curve) / rank
 
Normal rank
Property / cites work
 
Property / cites work: Electrical Impedance Tomography / rank
 
Normal rank
Property / cites work
 
Property / cites work: Q5515676 / rank
 
Normal rank
Property / cites work
 
Property / cites work: Dynamic inverse obstacle problems with electrical impedance tomography / rank
 
Normal rank
Property / cites work
 
Property / cites work: NETGEN: An advancing front 2D/3D-mesh generator based on abstract rules / rank
 
Normal rank
Property / cites work
 
Property / cites work: Analysis of Discrete Ill-Posed Problems by Means of the L-Curve / rank
 
Normal rank
links / mardi / namelinks / mardi / name
 

Latest revision as of 08:27, 5 July 2024

scientific article
Language Label Description Also known as
English
Modelling of an oesophageal electrode for cardiac function tomography
scientific article

    Statements

    Modelling of an oesophageal electrode for cardiac function tomography (English)
    0 references
    0 references
    0 references
    0 references
    19 June 2012
    0 references
    Summary: There is a need in critical care units for continuous cardiopulmonary monitoring techniques. ECG gated electrical impedance tomography is able to localize the impedance variations occurring during the cardiac cycle. This method is a safe, inexpensive and potentially fast technique for cardiac output imaging but the spatial resolution is presently low, particularly for central locations such as the heart. Many parameters including noise deteriorate the reconstruction result. One of the main obstacles in cardiac imaging at the heart location is the high impedance of lungs and muscles on the dorsal and posterior side of body. We investigate improvements of the measurement and initial conductivity estimation of the internal electrode by modelling an internal electrode inside the esophagus. We consider 16 electrodes connected around a cylindrical mesh. With the random noise level set near 0.05\% of the signal we evaluated the Graz consensus reconstruction algorithm for electrical impedance tomography. The modelling and simulation results showed that the quality of the target in reconstructed images was improved by up to 5 times for amplitude response, position error, resolution, shape deformation and ringing effects with perturbations located in cardiac related positions when using an internal electrode.
    0 references

    Identifiers

    0 references
    0 references
    0 references
    0 references
    0 references
    0 references
    0 references
    0 references