A new three-oscillator model for the heart system in the case of time delay and designing appropriate controller for its synchronization (Q469906): Difference between revisions

From MaRDI portal
Created claim: Wikidata QID (P12): Q59047495, #quickstatements; #temporary_batch_1705868726170
ReferenceBot (talk | contribs)
Changed an Item
 
(3 intermediate revisions by 3 users not shown)
Property / MaRDI profile type
 
Property / MaRDI profile type: MaRDI publication profile / rank
 
Normal rank
Property / full work available at URL
 
Property / full work available at URL: https://doi.org/10.1155/2014/168247 / rank
 
Normal rank
Property / OpenAlex ID
 
Property / OpenAlex ID: W2063225223 / rank
 
Normal rank
Property / cites work
 
Property / cites work: A Model of Two Nonlinear Coupled Oscillators for the Study of Heartbeat Dynamics / rank
 
Normal rank
Property / cites work
 
Property / cites work: An analysis of heart rhythm dynamics using a three-coupled oscillator model / rank
 
Normal rank
Property / cites work
 
Property / cites work: Synchronization in chaotic systems / rank
 
Normal rank
Property / cites work
 
Property / cites work: Dynamics of three coupled van der Pol oscillators with application to circadian rhythms / rank
 
Normal rank
links / mardi / namelinks / mardi / name
 

Latest revision as of 06:21, 9 July 2024

scientific article
Language Label Description Also known as
English
A new three-oscillator model for the heart system in the case of time delay and designing appropriate controller for its synchronization
scientific article

    Statements

    A new three-oscillator model for the heart system in the case of time delay and designing appropriate controller for its synchronization (English)
    0 references
    0 references
    0 references
    0 references
    0 references
    11 November 2014
    0 references
    Summary: If the \(SA\) and \(AV\) oscillators are not synchronized, it may arise some kinds of blocking arrhythmias in the system of heart. In this paper, in order to examine the heart system more precisely, we apply the three-oscillator model of the heart system, and to prevent arrhythmias, perform the following steps. Firstly, we add a voltage with rang \(a_1\) and \(\omega\) frequency to \(SA\) node. Then, we use delay time factor in oscillators and finally the appropriate control is designed. In this paper, we have explained how simulating and curing these arrhythmias are possible by designing a three-oscillator system for heart in the state of delay and without delay and by applying an appropriate control. In the end, we present the simulation results.
    0 references

    Identifiers

    0 references
    0 references
    0 references
    0 references
    0 references
    0 references
    0 references