Design of controlled structures
Conclusions: This paper provides a technique to answer the questions (i) ``for what performance requirements \((H_\infty\) bound) is active control necessary?. (ii) ``what is the optimal stiffness, damping and mass distribution throughout a structure? and (iii) ``what is the optimal distribution of control energy throughout a structure?NEWLINENEWLINE Such results depend strongly on the performance constrains imposed on the design. The method here integrates the structure design with the control design. The resultant system guarantees certain robustness \((H_\infty\) norm is bounded) and minimum control energy \((H_2\) norm is optimized). If for the given robustness requirement the minimum active control energy is zero, then a passive design to reach the guaranteed robustness is obtained. The method is illustrated for a simplified model of a 5-story building to obtain both passive and active designs.NEWLINENEWLINEFor the entire collection see [Zbl 0959.00020].
- Integrating structure and control design to achieve mixed H2/H performance
- Optimal mix of passive and active control in structures
- Integrated structural design and vibration suppression using independent modal space control
- scientific article; zbMATH DE number 4089085
- scientific article; zbMATH DE number 4047529
- Development control: structural analysis, problems, stability
- Optimum structural design and robust active control using singular value constraints
- Integrated design of large-scale collocated structural system and control parameters using a norm upper bound approach
- Efficiency of structure-control systems
- Modeling structures for control design
- scientific article; zbMATH DE number 4047529 (Why is no real title available?)
- scientific article; zbMATH DE number 41362 (Why is no real title available?)
- Optimal mix of passive and active control in structures
- Normes énergétiques caractérisant la réponse structurale
- scientific article; zbMATH DE number 2010069 (Why is no real title available?)
- Design and Analysis of Remote Center of Compliance Structures
- Integrating instrumentation and control design
- Integrating structure and control design to achieve mixed H2/H performance
- Optimal bounded-state control with application to building structure
- Passive control analysis and design of twin-tower structure with chassis
- Integrated layout design of supports and structures
- Effect of response related weighting matrices on performance of active control systems for nonlinear frames
This page was built for publication: Design of controlled structures
Report a bug (only for logged in users!)Click here to report a bug for this page (MaRDI item Q2725708)