Availability analysis of a two-unit series system with shut-off rule and ``first-fail, first repaired'' (Q2367938)

From MaRDI portal

!

This is the item page for this Wikibase entity, intended for internal use and editing purposes. Please use the normal view instead:

scientific article; zbMATH DE number 270056
Language Label Description Also known as
default for all languages
No label defined
    English
    Availability analysis of a two-unit series system with shut-off rule and ``first-fail, first repaired''
    scientific article; zbMATH DE number 270056

      Statements

      Availability analysis of a two-unit series system with shut-off rule and ``first-fail, first repaired'' (English)
      0 references
      0 references
      0 references
      17 August 1993
      0 references
      The authors consider a system consisting of two units in series and one repair facility with first-fail, first-repaired repair discipline. A failure of unit one shuts off unit two but not vice versa. Life times and repair times are all independent with general distributions. The authors present without proofs representations for the mean renewal period, the limiting availability and the failure frequency of the system.
      0 references
      repair facility
      0 references
      limiting availability
      0 references
      failure frequency
      0 references
      0 references